A Methodological Approach to Non-invasive Assessments of Vascular Function and Morphology
Published on: February 7, 2015
Drug- and temperature-induced changes in peripheral circulation measured by laser-Doppler flowmetry and digital-pulse
Abstract:
We measured the effects of a new transdermal nitroglycerin patch (25 mg, 10 cm2) applied for 24 h, norphenephrine (6 mg), prazosin (1 mg) as well as local heat and cold provocation on blood pressure, heart rate, skin blood flow (measured by laser-Doppler flowmetry, L-D) and peripheral arterial resistance (assessed by digital pulse plethysmography, D-P) in 15 healthy volunteers (aged 21-31 years). Heat provocation induced a three-fold increase in skin blood flow in the hand (p less than 0.001) and cold provocation a decrease in flow (p less than 0.05) of about 20%. Forehead skin blood flow did not change. Peripheral arterial resistance showed less consistent changes during the provocation tests. Prazosin increased the forehead skin blood flow (p less than 0.01) and decreased peripheral arterial resistance, while norphenephrine showed an opposite effect. Transdermal nitroglycerin induced an increase of 25% in forehead skin blood flow (p less than 0.05) which persisted for 24 h and a decrease in peripheral arterial resistance (p less than 0.02), but this effect was evident up to 8 h only. We conclude that (1) local heat and cold provocation mainly affected skin blood flow, (2) vasodilative and vasoconstrictive drugs showed marked changes in peripheral arterial resistance, but at different points in time from subject to subject, and (3) transdermal nitroglycerin patches induced haemodynamic changes persisting for up to 8-24 h.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment: