Related Experiment Video
Updated: Jan 27, 2026

Author Spotlight: Optimized Lung MRI Protocol with Computationally Efficient Reconstruction Methods
Published on: September 6, 2024
Automatic self-gated 4D-MRI construction from free-breathing 2D acquisitions applied on liver images
Liset Vázquez Romaguera1, Nils Olofsson2, Rosalie Plantefève3
1Polytechnique Montreal, Montreal, Canada. liset.vazquez@polymtl.ca.
Purpose:
MRI slice reordering is a necessary step when three-dimensional (3D) motion of an anatomical region of interest has to be extracted from multiple two-dimensional (2D) dynamic acquisition planes, e.g., for the construction of motion models used for image-guided radiotherapy. Existing reordering methods focus on obtaining a spatially coherent reconstructed volume for each time. However, little attention has been paid to the temporal coherence of the reconstructed volumes, which is of primary importance for accurate 3D motion extraction. This paper proposes a fully automatic self-sorting four-dimensional MR volume construction method that ensures the temporal coherence of the results.
Methods:
First, a pseudo-navigator signal is extracted for each 2D dynamic slice acquisition series. Then, a weighted graph is created using both spatial and motion information provided by the pseudo-navigator. The volume at a given time point is reconstructed following the shortest paths in the graph starting that time point of a reference slice chosen based on its pseudo-navigator signal.
Results:
The proposed method is evaluated against two state-of-the-art slice reordering algorithms on a prospective dataset of 12 volunteers using both spatial and temporal quality metrics. The automated end-exhale extraction showed results closed to the median value of the manual operators. Furthermore, the results of the validation metrics show that the proposed method outperforms state-of-the-art methods in terms of both spatial and temporal quality.
Conclusion:
Our approach is able to automatically detect the end-exhale phases within one given anatomical position and cope with irregular breathing.
More Related Videos
08:35Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
07:07Author Spotlight: High-Resolution 4D Light-Sheet Imaging and Virtual Reality in Zebrafish for Single-Cell Analysis of Heart Function
Published on: January 5, 2024
Related Concept Videos
Breathing
Automatic Processing and Automatic Social Behavior
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Ligand-Gated Ion Channel Receptor: Gating Mechanism
Underflow Gates
Mechanism of Breathing II: Expiration
Expiration, or exhaling, is a complex physiological process that begins as the inspiratory muscles begin to relax. This relaxation triggers a series of events that epitomize the efficiency of the respiratory system.
Mechanism of Expiration: