Related Experiment Video
Updated: Jan 27, 2026

Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Use of non-contrast-enhanced computed tomography to identify deep digital flexor tendinopathy in horses with
Objective:
To describe the use of non-contrast-enhanced CT to identify deep digital flexor (DDF) tendinopathy in horses with lameness attributed to pain in regions distal to the metatarsophalangeal or metacarpophalangeal joints.
Design:
Retrospective case series.
Animals:
28 client-owned horses.
Procedures:
Medical records were searched to identify horses that underwent non-contrast-enhanced CT with or without high-field MRI as part of an evaluation for lameness localized to areas distal to the metacarpophalangeal or metatarsophalangeal joint in ≥ 1 limb. Horses were included in the study if they had ≥ 1 DDF tendon lesion (DDF tendinopathy) identified. Signalment, lameness examination findings and response to perineural anesthesia, imaging modality, anesthetic agents and duration of anesthesia, and imaging findings were recorded. Data were summarized descriptively.
Results:
Bilateral imaging was performed for all horses, irrespective of unilateral or bilateral lameness. Nine of 28 horses underwent both CT and MRI, and all DDF tendon lesions identified by one modality were identified by the other. Of 48 limbs with DDF tendinopathy, 46 (96%) had core lesions and 35 (73%) had dorsal border irregularities. Median anesthesia time for CT and CT followed by MRI was 15 and 110 minutes, respectively.
Conclusions And Clinical Relevance:
Results suggested that non-contrast-enhanced CT was useful for identifying DDF tendinopathy in horses with lameness localized to the phalangeal regions, and this was supported by consistency of findings in a subset of horses that underwent MRI. Further research is needed to confirm these results.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Self-Evaluation: Self-Enhancement and Self-Verification
Bioavailability Enhancement: Drug Solubility Enhancement
Bioavailability Enhancement: Drug Permeability Enhancement