Related Experiment Video
Updated: Jan 27, 2026

How to Calculate and Validate Inter-brain Synchronization in a fNIRS Hyperscanning Study
Published on: September 8, 2021
Intra- and inter-site reproducibility of human brain single-voxel proton MRS at 3 T
Carina Graf1,2, Erin L MacMillan3,4,5, Eric Fu6
1Physics & Astronomy, University of British Columbia, Vancouver, British Columbia, Canada.
Introduction:
Clinical trials that involve participants from multiple sites necessitate standardized and reliable quantitative MRI outcomes to detect significant group differences over time. Metabolite concentrations measured by proton MRS (1 H-MRS) provide valuable information about in vivo metabolism of the central nervous system, but can vary based on the acquisition and quantitation methods used by different MR sites. Therefore, we investigated the intra- and inter-site reproducibility of metabolite concentrations measured by 1 H-MRS on MRI scanners from a single manufacturer across six sites.
Methods:
Five healthy controls were scanned twice within 24 h at six participating 3 T MR sites with large single-voxel PRESS (TE/TR/NSA = 36 ms/4000 ms/56) and anatomical images for voxel positioning and correction of partial volume relaxation. Absolute metabolite concentrations were calculated relative to the T1 and T2 relaxation corrected signal from water. Intra- and inter-site reproducibility was assessed using Bland-Altman plots and intra- and inter-site coefficient of variation (CoV) as well as intra- and inter-site intra-class correlation coefficient.
Results:
The median intra-site CoVs for the five major metabolite concentrations ([NAA], [tCr], [Glu], [tCho] and [Ins]) were between 2.5 and 5.3%. Inter-site CoVs were also low, with the median CoVs for all metabolites between 3.7 and 6.4%. Metabolite concentrations were robust to small inconsistencies in voxel placement and site was not the driving factor in the variance of the measurement of any metabolite concentration. Between-subject differences accounted for the majority of the concentration variability for creatine, choline and myo-inositol (42-65% of the variance).
Conclusion:
A large single-voxel 1 H-MRS acquisition from a single manufacturer's MRI scanner is highly reproducible and reliable for multi-site clinical trials.
Related Concept Videos
Proton (¹H) NMR: Chemical Shift
Absorption signals of all the protium nuclei...
¹H NMR of Labile Protons: Temporal Resolution
The –OH proton in alcohols typically appears in the range of δ 2 to 5 ppm but can vary depending on the specific...
¹H NMR of Labile Protons: Deuterium (²H) Substitution
ortho–para-Directing Activators: –CH3, –OH, –⁠NH2, –OCH3
¹H NMR Chemical Shift Equivalence: Homotopic and Heterotopic Protons
¹H NMR Chemical Shift Equivalence: Enantiotopic and Diastereotopic Protons
In chiral compounds such as 2-butanol, replacing the methylene hydrogens at C3 produces a pair of...