Cataract risk in US radiologic technologists assisting with fluoroscopically guided interventional procedures: a
Raquel Velazquez-Kronen1,2, David Borrego1, Ethel S Gilbert1
1Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, US Department of Health and Human Services, Rockville, Maryland, USA.
Objectives:
To assess radiation exposure-related work history and risk of cataract and cataract surgery among radiologic technologists assisting with fluoroscopically guided interventional procedures (FGIP).
Methods:
This retrospective study included 35 751 radiologic technologists who reported being cataract-free at baseline (1994-1998) and completed a follow-up questionnaire (2013-2014). Frequencies of assisting with 21 types of FGIP and use of radiation protection equipment during five time periods (before 1970, 1970-1979, 1980-1989, 1990-1999, 2000-2009) were derived from an additional self-administered questionnaire in 2013-2014. Multivariable-adjusted relative risks (RRs) for self-reported cataract diagnosis and cataract surgery were estimated according to FGIP work history.
Results:
During follow-up, 9372 technologists reported incident physician-diagnosed cataract; 4278 of incident cases reported undergoing cataract surgery. Technologists who ever assisted with FGIP had increased risk for cataract compared with those who never assisted with FGIP (RR: 1.18, 95% CI 1.11 to 1.25). Risk increased with increasing cumulative number of FGIP; the RR for technologists who assisted with >5000 FGIP compared with those who never assisted was 1.38 (95% CI 1.24 to 1.53; p trend <0.001). These associations were more pronounced for FGIP when technologists were located ≤3 feet (≤0.9 m) from the patient compared with >3 feet (>0.9 m) (RRs for >5000 at ≤3 feet vs never FGIP were 1.48, 95% CI 1.27 to 1.74 and 1.15, 95% CI 0.98 to 1.35, respectively; pdifference=0.04). Similar risks, although not statistically significant, were observed for cataract surgery.
Conclusion:
Technologists who reported assisting with FGIP, particularly high-volume FGIP within 3 feet of the patient, had increased risk of incident cataract. Additional investigation should evaluate estimated dose response and medically validated cataract type.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Nursing Interventions I: Taxonomy of Nursing Interventions
A nursing intervention is a treatment or action based on scientific concepts and knowledge from the nursing, behavioral, and physical sciences. Identifying and prioritizing nursing interventions based on the desired outcome...
Nursing Interventions II: Selecting and Classifying the Nursing Interventions
Relative Risk
Community Based Intervention
Foundations of Community Mental Health Programs
Central to the success of community-based interventions is the...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...