Background And Objective:
Detection of early vascular changes observed on optical coherence tomography angiography (OCTA) in children who have received external beam radiation and are at risk of developing radiation retinopathy (RR).
Patients And Methods:
Eleven pediatric patients (20 eyes) with history of irradiation and nine healthy subjects (14 eyes) were retrospectively studied after dilated fundus exam and imaging.
Results:
Four eyes of three patients had clinical RR. Eyes with radiation exposure but no RR had worse vision (no RR: logMAR 0.09 ± 0.14, Snellen 20/25) than controls (logMAR 0.01 ± 0.03, Snellen 20/21; P = .04) and increased superficial foveal avascular zone (FAZ) area (radiation: 0.31 ± 0.15 vs. control: 0.18 ± 0.10; P = .005). Eyes with RR had worse vision (RR: logMAR 0.34 ± 0.31, Snellen 20/44) than eyes with no RR (P = .001) and had increased deep FAZ (RR: 1.23 ± 0.40 vs. no RR: 0.68 ± 0.25; P = .01), but similar superficial FAZ (RR: 0.44 ± 0.28 vs. no RR: 0.31 ± 0.15; P = .42).
Conclusions:
Eyes with mildly decreased vision but no RR show superficial but not deep plexus changes. Eyes with RR have both superficial and deep plexus changes. [Ophthalmic Surg Lasers Imaging Retina. 2019;50:145-152.].
More Related Videos
05:08Targeted and Selective Treatment of Pluripotent Stem Cell-derived Teratomas Using External Beam Radiation in a Small-animal Model
Published on: February 17, 2019
07:18Evaluation of Capillary and Other Vessel Contribution to Macular Perfusion Density Measured with Optical Coherence Tomography Angiography
Published on: February 18, 2022
Related Concept Videos
Biological Effects of Radiation
Radiation: Applications
The average...
Absorption of Radiation
Generating Electromagnetic Radiations
Radiation Pressure: Problem Solving
The average value of the rate of momentum transfer divided by the absorbing area represents the average force...
Momentum And Radiation Pressure