A Study on Noise Reduction of Gear Pumps of Wheel Loaders Based on the ICA Model
Panling Huang1,2, Liang Xu3,4, Chuan Luo5,6
1School of Mechanical Engineering, Shandong University, Jinan 250061, China. hfpl@sdu.edu.cn.
Abstract:
In order to reduce the noise level of wheel loaders caused by gear pumps and realize environmentally sustainable development, the noise generation mechanism of a gear pump was studied, and the influence of flow pulsation and gear impact on noise was analyzed. In order to reduce the interference of other noise sources on the noise level of the gear pump, a noise test rig was established. The mixed noise signals obtained from the rig test were separated using the ICA model. The ICA model includes the following algorithms: The fast Fourier transform (FFT), independent component analysis (ICA) and inverse fast Fourier transform (IFFT). Some theories about the influence of the teeth number and teeth profile on noise were analyzed by theory and simulation. A noise reduction strategy was proposed by increasing the teeth numbers and modifying the teeth profile of the gear pump. The tests results showed that the noise values of the external and the driver's ear of the wheel loader were reduced to 1 and 2.2 dB (A), respectively. This proves the effectiveness of the optimization scheme of gear pump noise reduction.
Related Concept Videos
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Oxidation-Reduction Reactions
Pumped Concrete
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
Refrigerators and Heat Pumps
A household refrigerator removes heat from...
ATP Driven Pumps I: An Overview
There are four main types of ATP-driven pumps - P-type, V-type, F-type, and ABC transporter. All these pumps are of varying complexities and...