Related Experiment Video
Updated: Jan 27, 2026

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Low Rate of Complications Following Intramedullary Headless Compression Screw Fixation of Metacarpal Fractures
William J Warrender1, David E Ruchelsman2, Michael G Livesey1
1Thomas Jefferson University, Philadelphia, PA, USA.
Abstract:
Background: There has been a recent increase in the use of headless compression screws for fixation of metacarpal neck and shaft fractures as they offer several advantages, and minimal complications have been reported. This study aimed to evaluate the clinical complications and their solutions following retrograde intramedullary headless compression screw fixation of metacarpal fractures. We describe complications and the approach to their management. Methods: We performed a multicenter case series through retrospective review of all patients treated with intramedullary headless screw fixation of metacarpal fractures by 3 fellowship-trained hand surgeons. Patient demographics, implant used, type of complication, pre- and postoperative radiographs, operative reports, and sequelae were reviewed for each case. We defined complications as infection, loss of fixation, hardware failure, malrotation, nonunion, malunion, metal allergy, and any repeat surgical intervention. Results: Four complications (2.5%) were identified through the review of 160 total metacarpal fractures. One complication was a nickel allergy, one was a broken screw after repeat trauma, and 2 patients had bent intramedullary screws. Screw removal in 3 patients was simple and without complications or persistent limitations. One bent screw with a refracture was left in place. No serious complications were seen. Conclusion: Intramedullary screw fixation of metacarpal fractures is safe with a low incidence of complications (2.5%) that can be safely and effectively managed.
More Related Videos
07:41An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
12:25C-arm-Free Simultaneous OLIF51 and Percutaneous Pedicle Screw Fixation in a Single Lateral Position
Published on: September 16, 2022
Related Concept Videos
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Screw: Problem Solving
To evaluate the...
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Diabetes: Symptoms, Diagnosis, and Complications
Pneumonia III: Complications and Assessment