Related Experiment Video
Updated: Jan 27, 2026

Combination of Adhesive-tape-based Sampling and Fluorescence in situ Hybridization for Rapid Detection of Salmonella on Fresh Produce
Published on: October 18, 2010
Label-free strip sensor based on surface positively charged nitrogen-rich carbon nanoparticles for rapid detection of
Zonghan Wang1, Xiaolin Yao1, Rong Wang1
1College of Food Science and Engineering, Northwest A&F University, 22 Xinong Road, Yangling 712100, Shaanxi, China.
Abstract:
Lateral flow immunoassay (LFIA) is a class and widespread applied point-of-care biosensor in the rapid monitoring field. To address the matched antibodies and antibody labeling dependence in the conventional LFIAs, in this work, an innovative label-free LFIA was proposed for the sensitive detection of Salmonella enteritidis (S. enteritidis) by introducing a new nanoparticles-bacteria-antibody sandwich strategy in the sensor. Surface positively charged nitrogen-rich carbon (pNC) nanoparticles, synthesized via calcination and etching reactions, were used as adsorbent to capture bacteria as well as for generating signals. In the presence of target pathogens, bacterial cells could combine with pNC through electrostatic interaction and hydrogen bonding, then the complex would be captured specifically by the anti-bacteria monoclonal antibody (McAb) coated on the test line (T-line). With the accumulation of nanoparticles-bacteria, the color on T-line would be gradually deepened from nearly colorless to deep black. Importantly, the pNC-based immunoassay could exhibit high sensitivity for target pathogens detection with a linear range of 102-108 cfu mL-1 and a low detection limit of 102 cfu mL-1. Furthermore, this system was validated preliminarily to screen S. enteritidis in different food samples with recoveries ranging from 85% to 110%. Taking advantages of simplicity, label-free, convenience, and sensitivity, the pNC-based LFIA has the application potential for pathogenic microorganisms monitoring in food safety and early clinical diagnosis fields.
More Related Videos
06:19Author Spotlight: Advancing SERS Technology: Au@Carbon Dot Nanoprobes for Label-Free Analysis and Imaging
Published on: June 9, 2023
10:10Development of a Lateral Flow Immunochromatographic Strip for Rapid and Quantitative Detection of Small Molecule Compounds
Published on: November 13, 2021
Related Concept Videos
Formal Charges
The Nitrogen Cycle
Ions and Ionic Charges
Position-effect Variegation
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Position of Equilibrium in Acid-Base Reactions