Thomas Gandet1, Baris Ata Ozdemir1, Lucien Chassin Trubert1
1Department of Thoracic and Vascular Surgery, Arnaud de Villeneuve Hospital, Montpellier, France.
Background:
This study evaluated the outcome of physician-modified thoracic stent grafts for the treatment of dissecting aortic arch aneurysms after surgical treatment of acute type A dissection.
Methods:
From August 2016 through February 2018, 13 patients (8 men and 5 women) underwent thoracic endovascular aortic repair in which physician-modified thoracic stent grafts were used to treat dissecting aortic arch aneurysms after surgical treatment of acute type A dissection. Patients were a mean age of 70.7 ± 10 years (range, 43 to 82 years). Four patients were treated in an emergent setting for a symptomatic aortic arch aneurysm. The aneurysmal disease involved zone 0 in 10 patients and zone 2 in 3. Seven patients (48%) were treated using an aortic arch stent graft with a single fenestration, combined with cervical debranching in 4 patients. Six patients underwent total endovascular aortic arch repair using a double-fenestrated stent graft. Additional planned endovascular procedures were performed in 3 patients.
Results:
Median time for stent graft modifications was 18 minutes (range, 14 to 21 minutes). All the proximal entry tears in the arch were successfully excluded. The 30-day mortality rate was 0%. One patient (7.6%) had a stroke without permanent sequelae. The median length of stay was 5 days (range, 1 to 17 days). During follow up of 8 ± 6 months, there were no conversions to open repair, aortic rupture, paraplegia, or retrograde dissection.
Conclusions:
The use of physician-modified thoracic stent grafts for the treatment of dissecting aortic arch aneurysm after surgical treatment of acute type A dissection is feasible and effective. Durability concerns will need to be assessed in future studies.
Related Concept Videos
The Arch of Aorta
Encircling the heart, the coronary arteries form a ring-like structure before...
Thoracic Aorta
The Thoracic Cage: Sternum
The sternum is the elongated bony structure on the anterior side of the thoracic cage. It consists of three parts: the manubrium, the body, and the xiphoid...
The Thoracic Cage: Ribs
Parts of a Typical Rib
A typical rib has a head, neck, and body. The posterior end of the rib is called the head, followed by a narrow neck. The head articulates primarily with the costal...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...
Modified Boxplots
However, the box plot does not tell the reader about outliers - values that lie far from the center of the data. We can modify the standard box and whisker plot to identify the outliers and visualize the actual spread of the data in a sample.
Initially, we calculate the adjusted...