Related Experiment Video
Updated: Jan 27, 2026

Machine Learning Algorithms for Early Detection of Bone Metastases in an Experimental Rat Model
Published on: August 16, 2020
Comparison of five methods for detection of carbapenemases in Enterobacterales with proposal of a new algorithm
L Lucena Baeza1, N Pfennigwerth2, C Greissl1
1Institute for Medical Microbiology, Immunology and Hygiene, University Hospital of Cologne, Cologne, Germany.
Objectives:
The aim of this study was to evaluate the performance of five different carbapenemase tests and to develop an algorithm which will permit the detection of most common and rare carbapenemases in routine microbiology laboratories.
Methods:
The immunochromatographic tests CARBA-5 (NG), RESIST-4 O.K.N.V. (Coris), the colorimetric β-CARBA (BioRad), a newly developed carbapenem-inactivation method (CIM) supplemented with zinc (zCIM), and the Xpert Carba-R (Cepheid) were challenged with a collection of 189 molecularly characterized Enterobacterales isolates, including 146 carbapenemase producers (CPE): VIM (n = 48), OXA-48-like (n = 40), NDM (n = 29), KPC (n = 13), IMI (n = 9), IMP (n = 9), OXA-58 (n = 2), and GES (n = 2).
Results:
The overall sensitivity/specificity values for the five carbapenemase detection tests were 84.2% (CI 77.6-89.2%)/100% (CI 91.8-100%) for RESIST-4, 88.2% (CI 82.1-92.4%)/100% (CI 91.8-100%) for CARBA-5, 88.2% (CI 82.1-92.4%)/100% (CI 91.8-100%) for Xpert Carba-R, 73.7% (CI 66.2-80.0%)/100% (CI 93.4-99.0%) for β-CARBA, and 97.4% (CI 87.9-99.6%)/97.7% (CI 87.9-99.6%) for zCIM. The four common carbapenemases (KPC, OXA-48-like, NDM, and VIM) were detected with ≥97.6% sensitivity by all tests except for β-CARBA (76.6% (CI 68.4-83.2%)). IMI and GES were only detected by zCIM (sensitivity 90.9% (CI 62.3-98.4%)). Based on these results a new algorithm was developed, consisting of an immunochromatographic assay as the first test followed by zCIM, which allows detection of 99.3% of all carbapenemases assessed.
Conclusions:
Except for β-CARBA, all methods showed excellent sensitivity/specificity for the detection of the four most frequent carbapenemases. With the new algorithm, rare variants can also be detected. It is rapid, simple, and inexpensive and can be performed in any microbiology laboratory, as no PCR equipment is required.
Related Concept Videos
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Trial and Error and Algorithm
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...

