Rat Model of Photochemically-Induced Posterior Ischemic Optic Neuropathy
Published on: November 29, 2015
Correlation of peripapillary nerve fiber layer thickness with visual outcomes after decompression surgery in
Mohammad Taher Rajabi1, Mina Ojani1, Hamid Riazi Esfahani1
1Eye Research Center, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran.
Purpose:
To assess the correlation of peripapillary retinal nerve fiber layer (PRNFL) thickness with visual recovery in compressive optic neuropathy (CON) in patients with thyroid eye disease (TED).
Methods:
Twenty-three eyes of 13 consecutive patients with TED-related CON were prospectively recruited. Assessment of PRNFL by means of spectral domain optical coherence tomography (SD-OCT), visual field (VF) parameters, color vision, and visual acuity in logMAR were compared before and 6 months after decompression surgery in the operated eye for each patient, which in ten cases included both eyes. Decompression surgery was performed as medial and inferior wall decompression sparing the orbital strut by the same surgeon.
Results:
There was a significant correlation between the preoperative PRNFL average thickness and postoperative improvement in visual acuity among all patients (P = 0.048). This correlation was found to be significant in clinically non-edematous optic neuropathy cases (P = 0.023) but not in edematous optic neuropathy (P = 0.23). There was significant correlation between PRNFL thickness and improvement of postoperative mean deviation (MD) and pattern standard deviation (PSD) parameters in VF studies and in color vision scores (P = 0.005, P = 0.02, P = 0.01, respectively). Average PRNFL thickness and quadrantal PRNFL were all significantly reduced after decompression surgery in all of the cases (P = 0.024).
Conclusions:
PRNFL thickness measured by SD-OCT is correlated with visual recovery after decompression surgery in TED-related CON. In eyes with severe VF defect (MD worse than -10 dB), the ones with higher preoperative PRNFL thicknesses (>65 μm) had more improvement in MD compared with those with thin PRNFL measures (<60 μm).
Related Concept Videos
Correlations
Local Anesthetics: Differential Sensitivity of Nerve Fibers
Correlation and Causation
Correlation versus Causation
If the dependent variable increases or decreases when the independent variable increases, there is a positive or negative...
Predicting Reaction Outcomes
The Thyroid Gland
The follicles have a central cavity lined by simple cuboidal to squamous epithelial cells called follicular cells. These cells produce the glycoprotein...
Correlation
Two variables, for example, a and b, are said to be positively correlated if both variables move in the same direction. In other words, a positive correlation exists between two variables, a and b, if: