Related Experiment Video
Updated: Jan 27, 2026

A Spine Robotic-Assisted Navigation System for Pedicle Screw Placement
Published on: May 11, 2020
Influence of novel design alteration of pedicle screw on pull-out strength: A finite element study
Shota Takenaka1, Takashi Kaito1, Ken Ishii2
1Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, Suita, Japan.
Background:
We conducted a finite element study to assess the effectiveness of a novel pedicle screw design with two alterations in the distal and proximal portions.
Methods:
Finite element (FE) models of 24 vertebrae were constructed using computed tomographic data. Pull-out strength of 4 different pedicle screws were compared. The basic screw design was a dual threaded one (PS0), in which the proximal portion is double-threaded (cortical thread), and the distal portion is single-threaded (cancellous thread). In PS1, the inter-thread double-core shape was added to PS0 in the distal portion. Compared to PS0, in PS2, the proximal portion was elongated by 5 mm. PS3 had both PS1 and PS2 features. In addition, the 24 vertebrae were classified into 3 groups based on volumetric bone mineral density (vBMD) of the vertebral body: low <120 mg/cm3, moderate 120-170 mg/cm3, and high >170 mg/cm3.
Results:
The mean pull-out strengths (±SD) were 1137 ± 500 N, 1188 ± 520 N, 1191 ± 512 N, and 1242 ± 538 N for PS0, PS1, PS2, and PS3, respectively. In PS1, there was significant difference in the incremental ratio of pull-out strength to PS0 between the low and high vBMD groups (3.7 ± 1.6% vs. 5.0 ± 1.0%, p = 0.006). In PS2, there was a significant difference in the incremental ratio to PS0 between the moderate and high vBMD groups (7.6 ± 4.0% vs. 3.3 ± 1.8%, p < 0.001). In PS3, there was a significant difference in the incremental ratio to PS0 between the moderate and high vBMD groups (12.1 ± 4.8% vs. 8.5 ± 2.1%, p = 0.003).
Conclusions:
The two design alterations showed the combined additive effect in the PS3 design. The moderate vBMD group has a balanced bone property to reflect the combined effects of the PS1 and PS2 design alterations.
Related Concept Videos
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...
Elements and Compounds
Elements
Elements are classified as atomic or molecular based on the nature of their basic units. They are unique forms of matter with specific chemical and physical properties that cannot break down into smaller substances by ordinary chemical reactions. There...
Biopharmaceutical Factors Influencing Drug Product Design: Overview
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Study Designs in Epidemiology
Observational studies are those where the researcher does not intervene but rather observes natural variations. They include cross-sectional, cohort, and...
Study Design in Statistics
Does aspirin reduce the risk of heart attacks? Is one brand of fertilizer more effective at growing roses than another? Is fatigue as dangerous to a driver as the influence of alcohol? Questions like these are answered using randomized experiments with proper...