Related Experiment Video For Colorectal neoplasms
Updated: Jan 27, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
The value of single-source dual-energy CT imaging for discriminating microsatellite instability from microsatellite
Jingjun Wu1, Yue Lv1, Nan Wang1
1Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Xigang district, Zhongshan road, No.222, Dalian, China.
Objectives:
To demonstrate the value of single-source dual-energy computed tomography (ssDECT) imaging for discriminating microsatellite instability (MSI) from microsatellite stability (MSS) colorectal cancer (CRC).
Methods:
Thirty-eight and seventy-six patients with pathologically proven MSI and MSS CRC, respectively, were retrospectively selected and compared. These patients underwent contrast-enhanced abdominal ssDECT scans before any anti-cancer treatment. Effective atomic number (Eff-Z) in precontrast phase, slope k of spectral HU curve in precontrast (k-P), arterial (k-A), venous (k-V), and delayed phase (k-D), normalized iodine concentration in arterial (NIC-A), venous (NIC-V), and delayed phase (NIC-D), of tumors in two groups were measured by two reviewers. Consistency of measurements was tested by intra-class correlation coefficients (ICC). Mann-Whitney U test or Student's t test was used to compare above values between MSI and MSS. Multivariate logistic regression was used to analyze multiple parameters. Receiver operating characteristic curves were calculated to assess diagnostic efficacies.
Results:
Interobserver agreement was excellent (ICC > 0.80). MSI CRC had significantly lower values in all measurements (NIC-A, V, D; k-P, A, V, D; Eff-Z) than MSS CRC. For discriminating MSI from MSS CRC, the area under curve (AUC) using k-A was the highest (AUC, 0.803; sensitivity, 72.4%; specificity, 76.3%). The multivariate logistic regression (selection method, Enter) with combined ssDECT parameters (NIC-A, NIC-V, NIC-D, Eff-Z, k-P, k-A, k-V, k-D) significantly improved diagnostic capability with AUC of 0.886 (sensitivity, 81.6%; specificity, 81.6%).
Conclusions:
The combination of multiple parameters in ssDECT imaging by multivariate logistic regression provides relatively high diagnostic accuracy for discriminating MSI from MSS CRC.
Key Points:
• ssDECT generates multiple parameters for discriminating CRC with MSI from MSS. • ssDECT measurements for MSI CRC were significantly lower than MSS CRC. • Combination of ssDECT parameters further improves diagnostic capability for differentiation.
Related Concept Videos
Stereotypes, Prejudice, and Discrimination
Combustion Energy: A Measure of Stability in Alkanes and Cycloalkanes
Alkanes undergo combustion in the presence of excess oxygen and high-temperature conditions to give carbon dioxide and water. A combustion reaction is the energy source in natural gas, liquified...
Microtubule Instability
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Activation Energy

