Performance of ultrasound for detection of transjugular intrahepatic portosystemic shunt dysfunction: a meta-analysis
Wuttiporn Manatsathit1, Hrishikesh Samant2, Panadeekarn Panjawatanan3
1Division of Gastroenterology and Hepatology, University of Nebraska Medical Center, 982000 Nebraska Medical Center, Omaha, NE, 68198-2000, USA. shane.manatsathit@unmc.edu.
Purpose:
Although ultrasound has been widely used to evaluate transjugular intrahepatic portosystemic shunts (TIPS) patency, several studies have reported conflicting data regarding its performance. Therefore, we aimed to evaluate performance of ultrasound for detection of TIPS dysfunction by performing a meta-analysis.
Methods:
Literature search was performed for studies evaluating ultrasound for TIPS dysfunction, stenosis, and occlusion using PubMed, EMBASE, Scopus, and Cochrane Library through February 2019. Pooled sensitivity, specificity, log diagnostic odds ratio (LDOR), and area under curve (AUC) of summary receiver-operating characteristic were calculated. Subgroup analyses were performed according to ultrasonographic criteria and type of stent.
Results:
In total, 21 studies were evaluated. Pooled sensitivity, specificity, and LDOR of ultrasound for detection of TIPS dysfunction were 0.82 (0.67, 0.93), 0.58 (0.46, 0.70), and 1.77 (1.20, 2.35). Pooled sensitivity, specificity, and LDOR for TIPS stenosis were 0.80 (0.69, 0.90), 0.80 (0.69, 0.91), and 2.83 (1.88, 3.78). Pooled sensitivity, specificity, and LDOR for TIPS occlusion were 0.96 (0.92, 0.99), 1 (0.99, 1.00), and 6.28 (4.96, 7.60). AUCs of ultrasound for TIPS dysfunction, stenosis, and occlusion were 0.77, 0.86, and 0.95, respectively.
Conclusions:
Although ultrasound had excellent performance for TIPS occlusion and acceptable performance for TIP stenosis, most studies utilized bare metal stent, and therefore, application to current practice is limited. Ultrasound for TIPS dysfunction in the setting of covered metal stent appeared to have acceptable sensitivity of 0.82, but limited specificity of 0.58 and low LDOR of 1.77. A new noninvasive tool is needed for detection of TIPS dysfunction in the era of covered metal stent.
Related Concept Videos
Shunt Admittances
To model this effect, the method of images is employed. This method involves replacing the Earth with an image conductor that mirrors the original...
Directing Effect of Substituents: meta-Directing Groups
Performing a Simple Data Analysis using MS-Excel Function
SUM: This function calculates the total sum of a range of values. It's the foundation for aggregating data, essential for determining overall trends and totals in datasets.
AVERAGE: It computes the mean value of a given set of numbers, providing a quick insight into the central...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
meta-Directing Deactivators: –NO2, –CN, –CHO, –⁠CO2R, –COR, –CO2H
Exercise and Muscle Performance
Endurance exercises
Endurance exercises involve running, swimming, or cycling, which require repetitive movements with low force output. When a person engages in endurance exercise, a few noticeable changes occur in their skeletal muscles. For instance, the number of capillaries...