Droplet digital PCR improves urinary exosomal miRNA detection compared to real-time PCR
Cong Wang1, Qiang Ding2, Pamela Plant2
1Department of Radiation Oncology, Qilu Hospital of Shandong University, Shandong, China; Keenan Biomedical Research Centre, Li Ka Shing Knowledge Institute, St Michael's Hospital, Toronto, ON, Canada.
Object:
Quantification of urinary miRNAs can be challenging especially for low abundance miRNAs. We aimed to optimize the quantification of urinary exosomal miRNAs and compare the performance efficiency between droplet digital PCR (ddPCR) and real-time quantitative PCR (qPCR).
Methods:
We optimized a number of parameters for ddPCR such as annealing temperatures, annealing time and PCR cycle number. We also compared the performance of ddPCR and qPCR.
Results:
By comparing the fluorescence amplification separation, the optimal annealing temperature was 59 °C, optimal annealing time was 60s and optimal cycle number was 45 for measuring urinary exosomal miRNAs. ddPCR had much higher technical sensitivity compared to qPCR. The minimal detectable concentration of miR-29a was <50 copies/μL by ddPCR compared to 6473 copies/μL for qPCR. Also, ddPCR generated more consistent results for serially diluted samples compared to qPCR. ddPCR generated smaller within-run variations than qPCR though this did not reach statistical significance. It also resulted in better reproducibility with smaller between-run variations.
Conclusions:
Optimization of urinary exosomal miRNA ddPCR assay is dependent on assessing key variables including experimental annealing temperature and time as well as the number of PCR cycles. ddPCR has a higher sensitivity, reproducibility, and accuracy in comparison to qPCR.
Related Concept Videos
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
PCR
Overview of Exosomes
Stahl et al. discovered exosomes in 1983, but the exosomes were initially considered waste products released from the...
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Introduction to Urinary System
The kidneys are bean-shaped organs located in the retroperitoneal space, on either side of the vertebral column, between the T12 and L3 vertebrae. They are partially protected by the rib cage and surrounded by perirenal fat, which provides cushioning. They are responsible for urine formation and play critical roles in regulating blood pressure, electrolyte levels, and hormone production. The ureters...
Urinary Bladder
In males, the bladder is situated in front of the rectum, while in females, it is positioned anterior to the vagina and uterus. The bladder floor contains an inverted triangular area called the trigone, defined by the two ureteric...