Related Experiment Video
Updated: Jan 27, 2026

Determining and Controlling External Power Output During Regular Handrim Wheelchair Propulsion
Published on: February 5, 2020
Criterion Validity of Force and Power Outputs for a Commonly Used Flywheel Resistance Training Device and Bluetooth
Jonathon Weakley1,2, Bruno Fernández-Valdés3, Liam Thomas1
1Institute for Sport, Physical Activity and Leisure, Leeds Beckett University, Leeds, West Yorkshire, United Kingdom.
Abstract:
Weakley, J, Fernández-Valdés, B, Thomas, L, Ramirez-Lopez, C, and Jones, B. Criterion validity of force and power outputs for a commonly used flywheel resistance training device and bluetooth app. J Strength Cond Res 33(5): 1180-1184, 2019-Flywheels are a resistance training device that can increase lean body mass, strength, and power. However, because of their unique design and the inertia from the concentric portion directly relating to the force that is applied during the eccentric portion, monitoring the training stimulus can be difficult. Consequently, the aim of this study was to assess the validity of the kMeter app for quantifying force and power at a range of different isoinertial loads from a flywheel training device when compared against a criterion measure. Eleven subjects volunteered to take part in this study, with subjects completing between 5 and 35 repetitions of the harness squat with 0.05, 0.10, 0.15 kg·m isoinertial load. A synchronized dual force plate and tricamera optoelectronic setup was used as the criterion measure to calculate force and power output, while the kMeter app was used as the practical measure. Very large to nearly perfect relationships were observed between the 2 measures, with trivial to moderate bias reported. In addition, typical error of the estimate (TEE) was found to be <10% at all isoinertial loads. These findings suggest that the kMeter app, when used in conjunction with the kBox flywheel device, demonstrates acceptable levels of validity. However, because of the TEE, the kMeter app may not be able to accurately detect small differences and therefore be suitable for research purposes. These findings suggest that the kMeter app is an acceptable method of monitoring flywheel resistance training. Furthermore, it is advised that practitioners use mean power rather than mean force.
Related Concept Videos
Power Expended by a Constant Force
Common Ion Effect
Reliability and Validity
Routh-Hurwitz Criterion I
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
Routh-Hurwitz Criterion II
The first scenario occurs when a singular zero appears in the first column of the Routh table. This situation creates a division by zero issues. To resolve this, a small positive or negative number, denoted as epsilon (∈), is substituted for the zero. The stability analysis proceeds by assuming a sign for ∈. If ∈ is positive, any sign change in the first...
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.

