Related Experiment Video
Updated: Jan 27, 2026

Capillary Electrophoresis Separation of Monoclonal Antibody Isoforms Using a Neutral Capillary
Published on: January 16, 2017
Determination of Urinary Pterins by Capillary Electrophoresis Coupled with LED-Induced Fluorescence Detector
Wojciech Grochocki1, Magdalena Buszewska-Forajta, Szymon Macioszek
1Department of Biopharmacy and Pharmacodynamic, Medical University of Gdansk, 80-416 Gdansk, Poland. grochoo@gumed.edu.pl.
Abstract:
Urinary pterins have been found as potential biomarkers in many pathophysiological conditions including inflammation, viral infections, and cancer. However, pterins determination in biological samples is difficult due to their degradation under exposure to air, light, and heat. Besides, they occur at shallow concentration levels, and thus, standard UV detectors cannot be used without additional sample preconcentration. On the other hand, ultra-sensitive laser-induced fluorescence (LIF) detection can be used since pterins exhibit native fluorescence. The main factor that limits an everyday use of LIF detectors is its high price. Here, an alternative detector, i.e., light-emitted diode induced fluorescence (LEDIF) detector, was evaluated for the determination of pterins in urine samples after capillary electrophoresis (CE) separation. An optimized method was validated in terms of linearity range, limit of detection (LOD), limit of quantification (LOQ), intra- and interday precision and accuracy, sample stability in the autosampler, and sample stability during the freezing/thawing cycle. The obtained LOD (0.1 µM) and LOQ (0.3 µM) values were three-order of magnitude lower compared to UV detector, and two orders of magnitude higher compared to previously reported house-built LIF detector. The applicability of the validated method was demonstrated in the analysis of urine samples from healthy individuals and cancer patients.
More Related Videos
08:25Using a Fluorescent PCR-capillary Gel Electrophoresis Technique to Genotype CRISPR/Cas9-mediated Knockout Mutants in a High-throughput Format
Published on: April 8, 2017
07:54Analysis of AtHIRD11 Intrinsic Disorder and Binding Towards Metal Ions by Capillary Gel Electrophoresis and Affinity Capillary Electrophoresis
Published on: August 22, 2018
Related Concept Videos
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
One-Compartment Open Model: Urinary Excretion Data and Determination of k
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II