Intense Therapeutic Ultrasound for Treatment of Chronic Plantar Fasciitis: A Pivotal Study Exploring Efficacy,
Evelyn Heigh1, Laura Bohman2, Gary Briskin3
1Podiatric Surgeon, Summit Medical Group Arizona, Glendale, AZ.
Abstract:
Intense therapeutic ultrasound for chronic plantar fasciitis musculoskeletal tissue pain reduction was evaluated in a pivotal clinical trial examining effectiveness, safety, and patient tolerance. In this single-blinded study, 33 patients received 2 treatments that were 4 weeks apart on plantar fascia tissue along with conservative standard of care. Patients were followed for up to 6 months after the first treatment, receiving a physical examination and diagnostic ultrasound at each follow-up visit and completing patient-/subject-reported outcome measure and Foot Function Index surveys. The goal was to reduce overall pain by ≥25% on average and >25% individually. Hypoechoic area changes on diagnostic ultrasound and adverse events were measured. The percentage meeting pain reduction criteria at weeks 4, 8, 12, and 26 were 72%, 81%, 86%, and 79%, respectively. Mean pain scores at each visit were significantly different from baseline (p < .001) at -39%, -49%, -51%, and -44%. Hypoechoic lesions were found in all patients and decreased in size significantly (p < .05) at weeks 8 and 12 (-56% and -67%). Foot Function Index scores declined favorably from baseline (p < .001) at all time points (-32%, -46%, -49%, and -32%). The percentages of patients meeting satisfaction criteria were 72%, 85%, 90%, and 83%. The mean pain score during treatment 1 was 3.4, and during treatment 2, 2.9. Attrition of only 1 patient owing to pain occurred, after treatment 1. No adverse events occurred. Intense therapeutic ultrasound for chronic plantar fasciitis is shown to be effective, safe, and well tolerated in this pivotal clinical trial.
More Related Videos
02:15Predictive Measurement for Windlass Change in Length and Selected Treatment Outcomes in Chronic Plantar Fasciitis
Published on: March 1, 2024
08:08Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System
Published on: March 6, 2019
Related Concept Videos
Pivot Bearings
A pivot bearing is a specialized type of bearing designed to support axial loads on a rotating shaft. The bearing surface, or the pivot, is positioned at the end of a shaft to support the axial thrust. The pivot may...
Survey Safety
Self-Efficacy
Sound Intensity
Household Wiring And Electrical Safety
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and...
