Related Experiment Video
Updated: Jan 27, 2026

Biomechanical Testing of Murine Tendons
Published on: October 15, 2019
Biomechanical Testing of a 3D-printed L5 Vertebral Body Model
Michael A Bohl1, Clinton D Morgan1, Michael A Mooney1
1Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, USA.
Abstract:
Background We examined the biomechanical performance of a three-dimensional (3D)-printed vertebra on pedicle screw insertional torque (IT), axial pullout (APO), and stiffness (ST) testing. Materials and methods Seventy-three anatomically identical L5 vertebral body models (146 pedicles) were printed and tested for IT, APO, and ST using single-threaded pedicle screws of equivalent diameter (6.5 mm), length (40.0 mm), and thread pitch (2.6 mm). Print properties (material, cortical thickness [number of shells], cancellous density [in-fill], in-fill pattern, print orientation) varied among models. One-way analysis of variance was performed to evaluate the effects of variables on outcomes. Results The type of material significantly affected IT, APO, and ST (P < 0.001, all comparisons). For acrylonitrile butadiene styrene (ABS) models, in-fill density (25-35%) had a positive linear association with APO (P = 0.002), ST (P = 0.008), and IT (P = 0.10); similarly for the polylactic acid (PLA) models, APO (P = 0.001), IT (P < 0.001), and ST (P = 0.14). For the nylon material type, in-fill density did not affect any tested parameter. For a given in-fill density, material, and print orientation, the in-fill pattern significantly affected IT (P = 0.002) and APO (P = 0.03) but not ST (P = 0.23). Print orientation also significantly affected IT (P < 0.001), APO (P < 0.001), and ST (P = 0.002). Conclusions 3D-printed vertebral body models with specific print parameters can be designed to perform analogously to human bone on pedicle screw tests of IT, APO, and ST. Altering the material, in-fill density, in-fill pattern, and print orientation of synthetic vertebral body models could reliably produce a model that mimics bone of a specific bone mineral density.
Related Concept Videos
Muscles of the Vertebral Column
Superficial Layer:
The superficial layer consists primarily of the splenius muscles, which include the splenius capitis and splenius cervicis. These muscles are mainly responsible for the head and cervical spine movements, including extension, rotation, and lateral bending. The splenius capitis...
Articulations of the Vertebral Column
Vertebral Column: Regions and Curvature
Regions of the Vertebral Column
In an adult, the spine is subdivided into five regions: the cervical, the thoracic, the lumbar, the sacral, and the coccygeal region. The spine initially develops as a series of 33 vertebrae; after 20 years of age, the nine bones in the sacral region, five sacral, and four coccygeal bones fuse to form...
Body Temperature
The average body temperature is approximately 37°C (98.6°F) and typically ranges from 36.1–37.2°C...
Body Temperature
Centroid of a Body
For a homogeneous body with constant density, the centroid can usually be found using equations representing a balance of the moments of the body's volume. If the...

