Related Experiment Video For Dynamic positron emission tomography (PET)
Updated: Jan 27, 2026

Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
Preliminary clinical assessment of dynamic 18F-fluorodeoxyglucose positron emission tomography/computed tomography
Takayoshi Shinya1, Yoichi Otomi2, Michiko Kubo2
1Department of Radiology, Tokushima University Hospital, 2-50-1, Kuramoto-cho, Tokushima City, Tokushima, 770-8503, Japan. midnight-2005@nifty.com.
Objective:
We assessed the diagnostic capacity of dynamic fluorine-18-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) and dual-time-point (DTP) PET/CT to explore the optimal scan timing for nodal staging in lung cancer.
Methods:
Thirty-four patients with lung cancer underwent dynamic and consecutive DTP PET/CT scans. Two readers visually evaluated FDG uptake within each lymph node (LN) and pulmonary artery (metastatic LN: n = 10; nonmetastatic LN: n = 121). For each dynamic and DTP scan, we compared the maximum standardized uptake value (SUVmax) and the retention index of the SUVmax (RI-SUVmax) between metastatic and nonmetastatic LNs. We compared the diagnostic capacity of the dynamic and DTP scans using receiver operating characteristic (ROC) analyses.
Results:
In the visual analyses of LN metastases, a sensitivity of 20.0-60.0% and specificity of 97.5-100.0% were identified for the first to third dynamic scans. The sensitivity of the 1-h early and 2-h delayed scans was 80.0% and 90.0%, respectively, whereas the specificity was 66.9% and 47.9%, respectively. The visual analysis of the dynamic second phase had the highest accuracy. Semiquantitative analyses revealed that the SUVmax was significantly higher for metastatic LNs than for nonmetastatic LNs in the dynamic second and third phases and the 1-h early and 2-h delayed phases (p < 0.05 for all). The RI-SUVmax was higher in metastatic LNs than in nonmetastatic LNs for the dynamic scan (p = 0.004) and the DTP scan (p = 0.002). The ROC analyses showed that SUV2 and SUV3 had higher performances with high specificity, high negative predictive value, and high accuracy than the other parameters. The area under the ROC curve of the RI-SUV-dual-time-point had the highest value (0.794) without any significant differences between the area under the ROC curves for all parameters (p > 0.05 for all).
Conclusions:
Based on the visual and semiquantitative analyses, 18F-FDG dynamic PET/CT exhibited excellent performance with extremely high specificity in the dynamic second phase.
More Related Videos
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Detailed Structure and Function of Lymph Nodes
From a histological perspective, lymph nodes can be split into two main areas: the superficial cortex and the deep medulla. The outer cortex is populated by dendritic cells, macrophages, and B lymphocytes, which are densely packed into follicles. When these B-lymphocytes are presented...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...