Related Experiment Video
Updated: Jan 27, 2026

Fluorescence Imaging with One-nanometer Accuracy FIONA
Published on: September 26, 2014
A smartphone fluorescence imaging-based mobile biosensing system integrated with a passive fluidic control cartridge
Won-Il Lee1, Younghyeon Park, Jaemin Park
1Samsung Advanced Institute for Health Sciences & Technology (SAIHST), Sungkyunkwan University, Suwon, Gyeonggi-do 16419, Republic of Korea.
Abstract:
A key challenge for realizing mobile device-based on-the-spot environmental biodetection is that a biosensor integrated with a fluid handling sensor cartridge must have acceptable accuracy comparable to that of conventional standard analytical methods. Furthermore, the user interface must be easy to operate, technologically plausible, and concise. Herein, we introduced an advanced smartphone imaging-based fluorescence microscope designed for Hg2+ monitoring by utilizing a biosensor cartridge that reduced user intervention via time-sequenced passive fluid handling. The cartridge also employed a metal-nanostructured plastic substrate for complementing the fluorescence signal output; this helped the realization of high-accuracy detection, in which a ratiometric dual-wavelength detection method was applied. Using 30 samples of Hg2+-spiked wastewater, we showed that our device, which has a detection limit of ∼1 pM, can perform analytical assays accurately. The detection results from our method were in good linearity and agreement with those of conventional standard methods. We conclude that the integration of a simple-to-use biosensor cartridge, fluorescence signal-enhancing substrate, dual-wavelength detection, and quantitative image data processing on a smartphone has great potential to make any population accessible to small-molecule detection, which has been performed in centralized laboratories for environmental monitoring.
Related Concept Videos
Community Based Intervention
Foundations of Community Mental Health Programs
Central to the success of community-based interventions is the...
Improving Translational Accuracy
Improving Translational Accuracy
Uncertainty in Measurement: Accuracy and Precision
Nursing Interventions I: Taxonomy of Nursing Interventions
A nursing intervention is a treatment or action based on scientific concepts and knowledge from the nursing, behavioral, and physical sciences. Identifying and prioritizing nursing interventions based on the desired outcome...
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...

