Correlation Between Cone-Beam Computed Tomography and High-Resolution Peripheral Computed Tomography for Assessment
Karen Mys1,2, Peter Varga2, Boyko Gueorguiev2
1Biomechanics Section, Mechanical Engineering, KU Leuven, Leuven, Belgium.
Abstract:
High-resolution peripheral quantitative computed tomography (HR-pQCT) is considered as the best technique to measure bone microarchitecture in vivo. However, a breakthrough for medical applications is inhibited because of the restricted field of view (∼9 mm) and a relatively long acquisition time (∼3 minutes). The goal of this study was to compare the accuracy of cone-beam computed tomography (CBCT) and HR-pQCT and to determine the agreement between CBCT and HR-pQCT in quantifying bone structural parameters. Nineteen trapezia of arthritic patients were scanned four times ex vivo: 1) CBCT (NewTom 5G, Cefla, at 75 μm); 2) HR-pQCT (XTremeCT-I, Scanco, at 82 μm); 3) HR-pQCT (XTremeCT-II, Scanco, at 60.7 μm); and 4) microCT (SkyScan1172, Bruker, at 19.84 μm). XTremeCT-I and XtremeCT-II were reconstructed, segmented, and analyzed following the manufacturer's guidelines. CBCT was reconstructed with in-house developed software and analyzed twice: once with an adaptive segmentation technique combined with a direct analysis method (AT-DM) and once with a Laplace-Hamming filtering technique combined with an indirect analysis method (LH-IM). Parameters of interest included bone volume fraction (BV/TV) and trabecular thickness (Tb.Th), separation (Tb.Sp), and number (Tb.N). The analyses of the CBCT data showed that the AT-DM analysis correlated better with microCT for BV/TV, Tb.Sp, and Tb.N, whereas the LH-IM technique correlated better for Tb.Th. Evaluated over all parameters, the coefficient of determination for XtremeCT-I, XtremeCT-II, and CBCT were higher as R2 = 0.68, 0.72, and 0.67, respectively. For CBCT, the correlations improved when three samples with very thin trabeculae close to each other were excluded and became similar to those for XtremeCT-I and XtremeCT-II. Interesting for clinical practice is that those bones could be identified automatically with the CBCT scanner. We conclude that CBCT produced similar accuracy as HR-pQCT in bone morphometric analyses of trapezia. The broader range of application, larger field of view, and shorter acquisition time make CBCT a valuable alternative to HR-pQCT. © 2019 American Society for Bone and Mineral Research.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Design Example: Traverse Angle Computations
Area Computation by the Alternative Coordinate Method
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
The Role of Ion Channels in Neuronal Computation
Sometimes a single EPSP is strong enough to induce an action potential in the postsynaptic neuron. However, multiple presynaptic inputs must often create EPSPs around the same time for the postsynaptic neuron to be sufficiently depolarized to fire an action potential....