Reduced motion and improved rectal dosimetry through endorectal immobilization for prostate stereotactic body
Jeremiah de Leon1, Michael G Jameson2,3,4, David Rivest-Henault5
11 Illawara Cancer Care Centre , Wollongong , Australia.
Objective:
PROMETHEUS (ACTRN12615000223538) is a multicentre clinical trial investigating the feasibility of 19 Gy in 2 fractions of stereotactic body radiotherapy (SBRT) as a boost technique for prostate cancer. The objective of this substudy was to evaluate intrafraction motion using cine MRI and assess the dosimetric impact of using a rectal displacement device (RDD).
Methods:
The initial 10 patients recruited underwent planning CT and MRI, with and without a RDD. Cine MRI images were captured using an interleaved T2 HASTE sequence in sagittal and axial planes with a temporal resolution of 5.2 s acquired over 4.3 min. Points of interest (POIs) were defined and a validated tracking algorithm measured displacement of these points over the 4.3 min in the anteroposterior, superior-inferior and left-right directions. Plans were generated with and without a RDD to examine the impact on dosimetry.
Results:
There was an overall trend for increasing displacement in all directions as time progressed when no RDD was in situ . points of interest remained comparatively stable with the RDD. In the sagittal plane, the RDD resulted in statistically significant improvement in the range of anteroposterior displacement for the rectal wall, anterior prostate, prostate apex and base. Dosimetrically, the use of a RDD significantly reduced rectal V16, V14 and Dmax, as well as the percentage of posterior rectal wall receiving 8.5 Gy.
Conclusion:
The RDD used in stereotactic prostate radiotherapy leads to reduced intrafraction motion of the prostate and rectum, with increasing improvement with time. It also results in significant improvement in rectal wall dosimetry.
Advances In Knowledge:
It was found that the rectal displacement device improved prostate stabilization significantly, improved rectum stabilization and dosimetry significantly. The rectal displacement device did not improve target volume dosimetry.
More Related Videos
05:32Povidone Iodine Rectal Preparation at Time of Prostate Needle Biopsy is a Simple and Reproducible Means to Reduce Risk of Procedural Infection
Published on: September 21, 2015
11:38Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Equation of Motion for a Rigid Body
The combined moments generated about the center of mass of the object are equal to the rate of change of the angular momentum of the body. An external force, when applied at a different...
Planar Rigid-Body Motion
Planar motion is typically divided into three distinct categories. The first is rectilinear translation, demonstrated by a subway train that moves along...
Reduced Mass Coordinates: Isolated Two-body Problem
Equation of Motion: General Plane motion
Moreover, the body's center of mass experiences a rotational effect as a result of these couple moments. This rotation can be articulated as the...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...