Relative versus absolute rises in T/QRS ratio by ST analysis of fetal electrocardiograms in labour: A case-control
Alexandra D J Hulsenboom1, Kim M J Verdurmen1, Rik Vullings2
1Department of Obstetrics and Gynaecology, Máxima Medical Centre, Veldhoven, the Netherlands.
Introduction:
The additional value of ST analysis during labour is uncertain. In ST analysis, a T/QRS baseline value is calculated from the fetal electrocardiogram and successive T/QRS ratios are compared to this baseline. However, variation in the orientation of the electrical heart axis between fetuses may yield different T/QRS baseline values. In case of a higher T/QRS baseline value more ST events are encountered, although not always related to perinatal outcome. We hypothesised that we can partly correct for this effect by analysing T/QRS rises as a percentage from baseline (relative ST analysis). This study aimed to explore whether relative ST analysis has better diagnostic value for cord acidaemia compared to conventional ST analysis, where predefined fixed T/QRS ratios are used.
Methods And Materials:
A case-control study was performed in 20 term human fetuses during labour; 10 cases (umbilical cord artery pH <7.05 at birth, defining acidaemia) and 10 controls (pH >7.20) were included. The fetal electrocardiogram was recorded using a STAN monitor. We electronically extracted all T/QRS values, baseline and episodic ST events from the STAN monitor and calculated the relative T/QRS changes. The cut-off for relative ST events was determined in a receiver operator characteristic (ROC) curve at optimal specificity for cord acidaemia. Parameters of interest were area under the curve (AUC) of the ROC curve for relative ST events and test performance of both conventional and relative ST analysis.
Results:
Relative ST analysis showed an AUC of 0.99. The optimal cut-off value for relative T/QRS rise was determined at 0.70. Relative vs conventional (absolute) ST analysis showed a specificity of 100% vs 40% (p = 0.031); sensitivity 90% vs 90%; positive likelihood ratio infinity vs 1.5; negative likelihood ratio 0.10 vs 0.25, respectively.
Conclusion:
Relative ST analysis seems to be a promising method to detect impending fetal acidaemia during labour. Further studies are required to determine the diagnostic accuracy.
Related Concept Videos
Bioavailability Study Design: Absolute Versus Relative Bioavailability
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the...
Relative Motion Analysis - Acceleration
Relative Motion Analysis - Velocity
When an external force is exerted, it sets the crank into a rotational movement. This, in turn, instigates the motion of the connecting rod, leading to what is referred to as a general plane motion. This process involves two key points - point A on the connecting rod...