Related Experiment Video
Updated: Jan 27, 2026

Orthopedic Robot-Assisted Femoral Neck System in the Treatment of Femoral Neck Fracture
Published on: March 3, 2023
Failure Patterns of Femoral Neck Fracture Fixation in Young Patients
Abstract:
The primary purpose of this study was to describe the failure patterns of femoral neck fracture fixation in young patients. The secondary purpose was to determine if pattern of failure varies by type of implant. Adult patients (age range, 18-55 years) who experienced a "fixation failure" following internal fixation of a femoral neck fracture were identified from 5 level 1 trauma centers. Failure was defined by screw cutout, implant breakage, varus collapse (<120° neck-shaft angle), or severe fracture shortening (≥1 cm). When multiple complications were identified, mechanical failures were preferentially noted for the analysis. Failure patterns were compared between patients who received multiple cancellous screws and patients who received a sliding hip screw plus a derotation screw. Severe fracture shortening was the most common complication identified (61%). No differences in the incidence of severe shortening (P=.750) or implant breakage (P=1.000) were detected between the fixation groups. However, among the failures with a sliding hip screw plus a derotation screw construct, a greater portion were related to screw cutout (38% for a sliding hip screw plus a derotation screw vs 7% for screws, P=.019). Failures with multiple screws were associated with varus collapse (25% for screws vs 0% for a sliding hip screw plus a derotation screw, P=.037). Severe shortening was the most common fixation failure. Sliding hip screw plus derotation screw implants were associated with screw cutout. Multiple cancellous screw implants failed by varus collapse. Selecting a surgical implant based on its likely failure pattern may allow surgeons to minimize the severity of failure or the need for secondary conversion to hip arthroplasty. [Orthopedics. 2019; 42(4):e376-e380.].
Related Concept Videos
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Muscles of the Anterior Neck
Arteries of the Head and Neck
The internal carotid arteries supply blood to the anterior portion of the cerebrum. They enter the...
Veins of Head and Neck
On the other hand, the vertebral veins, unlike their arterial counterparts, are not primarily responsible for brain drainage. Instead, they drain the cervical vertebrae, spinal cord, and some small...
Carbon-dioxide Fixation
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...

