Related Experiment Video
Updated: Jan 27, 2026

Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
Preclinical voxel-based dosimetry through GATE Monte Carlo simulation using PET/CT imaging of mice
Arun Gupta1, Min Sun Lee1,2, Joong Hyun Kim3
1Department of Nuclear Medicine, College of Medicine, Seoul National University, Seoul, Republic of Korea.
None:
Internal dosimetry is of critical importance to obtain an accurate absorbed dose-response relationship during preclinical molecular imaging and targeted radionuclide therapy (TRT). Conventionally, absorbed dose calculations have been performed using organ-level dosimetry based on the Medical Internal Radiation Dose (MIRD) schema. However, recent research has focused on developing more accurate voxel-level calculation methods. Geant4 application for emission tomography (GATE) Monte Carlo (MC) is a simulation toolkit gaining attention in voxel-based dosimetry. In this study, we used PET/CT images of real mice to estimate the absorbed doses in sensitive organs at voxel-level to evaluate the suitability of GATE MC simulation for preclinical dosimetry. Thirteen normal C57BL/6 mice (male, body weight: 27.71 ± 4.25 g) were used to acquire dynamic positron emission tomography/computed tomography (PET/CT) images after IV injection of 18F-FDG. GATE MC toolkit was applied to estimate the absorbed doses in various organs of mice at voxel-level using CT and PET images as voxelized phantom and voxelized source, respectively. In addition, mean absorbed dose at organ-level was calculated using MIRD schema for comparison purposes. The differences in the respective absorbed doses (mGy MBq-1) between GATE MC and MIRD schema for brain, heart wall, liver, lungs, stomach wall, spleen, kidneys, and bladder wall were 1.36, 12.3, -22.4, -11.2, -16.9, -2.87, -4.29, and 3.71%, respectively. Considering that the PET/CT data of real mice were used for GATE simulation, the absorbed doses estimated in this study are mouse-specific. Therefore, the GATE-based Monte Carlo is likely to allow for more accurate internal dosimetry calculations. This method can be used in TRT for personalized dosimetry because it considers patient-specific heterogeneous tissue compositions and activity distributions.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
11:34Murine Lymphocyte Labeling by 64Cu-Antibody Receptor Targeting for In Vivo Cell Trafficking by PET/CT
Published on: April 29, 2017
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Ligand-Gated Ion Channel Receptor: Gating Mechanism
Underflow Gates
Non-gated Ion Channels
Compared to the gated ion channels, the non-gated channels, also known as leakage or passive channels, have no gating mechanism....