Background/Objective:
Axillary lymph node staging (ALNS) is an important step in the treatment of breast cancer and sentinel lymph node biopsy (SLNB) is a standard procedure for ALNS. Recently, the use of positron emission tomography/computed tomography (PET/CT) for whole body staging in patients with breast cancer has been increasing. The negative predictive value (NPV) of the specific diagnostic modality is the crucial value for excluding axillary lymph node metastasis (ALNM) and guiding the decision not to proceed with axillary lymph node dissection. The aim of this study was to identify patient groups in which PET/CT yields a high NPV for ALNS.
Methods:
We reviewed data from the records of 262 patients with breast cancer who underwent PET/CT before surgery between February 2009 and March 2018. We searched for factors associated with pathological axillary lymph node metastasis in patients with negative ALNM on PET/CT. Then, we calculated the NPV of PET/CT for ALNS in the patient group without the identified factors and in all patients.
Results:
Age ≥75 years and tumor size on ultrasonography (US) ≥ 15 mm were the associated factors; the NPV of PET/CT in patients without these factors compared to all patients was 97.2% versus 88.7%.
Conclusion:
The NPV of PET/CT for ALNS in patients younger than 75 years and with tumor size on US < 15 mm is higher than that in all patients and comparable to the NPV of SLNB reported in previous studies (90.1-97.0%).
More Related Videos
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
05:32Multimodal Bioluminescent and Positronic-emission Tomography/Computational Tomography Imaging of Multiple Myeloma Bone Marrow Xenografts in NOG Mice
Published on: January 7, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Detailed Structure and Function of Lymph Nodes
From a histological perspective, lymph nodes can be split into two main areas: the superficial cortex and the deep medulla. The outer cortex is populated by dendritic cells, macrophages, and B lymphocytes, which are densely packed into follicles. When these B-lymphocytes are presented...
Emission Spectra