Safety of Positive Pressure Extubation Technique

Mauro F Andreu1,2,3, María E Dotta2, Marco G Bezzi2

  • 1Department of Health Sciences, Physical Therapy, Universidad de la Matanza, San Justo, Buenos Aires, Argentina. maufede@hotmail.com.

Respiratory Care
|March 28, 2019
PubMed
Abstract

Related Concept Videos

Endotracheal Tube Extubation01:24

Endotracheal Tube Extubation

Endotracheal tube extubation is a critical procedure in weaning patients from mechanical ventilation. It involves physically removing the oral or nasal endotracheal (ET) tube, marking the final step in liberating a patient from ventilatory support.
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
4.0K
Survey Safety01:28

Survey Safety

Surveying near highways, rough terrain, or power lines involves significant risks. Working along highways is particularly dangerous and requires the use of warning signs and flagmen. It is safest to avoid working directly on roads and use offsets whenever possible. When highway work is unavoidable, it must follow all safety guidelines. Surveyors should wear bright clothing, such as orange reflective vests, to ensure visibility to motorists, coworkers, and hunters. In construction zones, wearing...
384
Household Wiring And Electrical Safety01:13

Household Wiring And Electrical Safety

Companies that supply power to most modern households use three conductors, typically called a three-wire line. While one is neutral, the other two are both at 120 V but with opposite polarity, giving a voltage of 240 V between them. With a three-wire line, high-power appliances that require 240 V, such as electric stoves and clothes dryers, are linked between the two hot lines. 120 V appliances can be connected between the neutral and either of the hot lines. The neutral side, which is always...
1.6K
Position-effect Variegation02:32

Position-effect Variegation

In 1928, a German botanist Emil Heitz observed the moss nuclei with a DNA binding dye. He observed that while some chromatin regions decondense and spread out in the interphase nucleus, others do not. He termed them euchromatin and heterochromatin, respectively. He proposed that the heterochromatin regions reflect a functionally inactive state of the genome. It was later confirmed that heterochromatin is transcriptionally repressed, and euchromatin is transcriptionally active chromatin.
7.0K
Serial Position Effect01:03

Serial Position Effect

The serial position effect is a cognitive phenomenon where individuals are more likely to recall the first and last items in a list compared to those in the middle. This effect is divided into the primacy effect and the recency effect. The primacy effect is observed when the initial items in a list are remembered better. This occurs because these items are rehearsed more frequently or receive more elaborative processing, allowing them to be encoded into long-term memory more effectively. For...
539
Vapor Pressure02:34

Vapor Pressure

When a liquid vaporizes in a closed container, gas molecules cannot escape. As these gas phase molecules move randomly about, they will occasionally collide with the surface of the condensed phase, and in some cases, these collisions will result in the molecules re-entering the condensed phase. The change from the gas phase to the liquid is called condensation. When the rate of condensation becomes equal to the rate of vaporization, neither the amount of the liquid nor the amount of the vapor...
40.2K