Low-voltage efficient electroosmotic pumps with ultrathin silica nanoporous membrane

Qian Yang1, Bin Su1, Yafeng Wang1

  • 1Institute of Analytical Chemistry, Department of Chemistry, Zhejiang University, Hangzhou, P. R. China.

Electrophoresis
|March 28, 2019
PubMed

Related Concept Videos

Voltage01:13

Voltage

The movement of electrons in a conductor requires some form of energy or work, usually provided by an external force, like a battery. This force is called the electromotive force or voltage. The voltage between two points, referred to as points "a" and "b," in an electric circuit is the energy (or work) needed to move a unit charge from point "a" to point "b," and this relationship is expressed mathematically as
4.1K
ATP Driven Pumps III: V-type Pumps01:30

ATP Driven Pumps III: V-type Pumps

V-type pumps are ATP-driven pumps found in the vacuolar membranes of plants, yeast, endosomal and lysosomal membranes of animal cells, plasma membranes of a few specialized eukaryotic cells, and some prokaryotes. They are also known as the V1Vo-ATPase, that couple ATP hydrolysis to transport protons against a concentration gradient.
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
4.7K
ATP Driven Pumps II: P-type Pumps01:34

ATP Driven Pumps II: P-type Pumps

The P-type pumps are a large family of integral membrane transporter ATPases. They are divided into five major types based on substrate specificity, from I to V.
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
6.2K
Pumped Concrete01:13

Pumped Concrete

Concrete in large quantities can be pumped across long distances for placing in inaccessible sites. This system comprises a hopper that receives concrete from a mixer, a pump to propel the concrete, and pipelines that facilitate its delivery.
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
370
Voltage Dividers01:14

Voltage Dividers

In electrical circuits, resistors can be connected in series, sequentially linked one after the other. In a series configuration, the same current flows through each resistor. Ohm's law is a fundamental principle to understand the behavior of resistors in series. It expresses the voltage across these resistors in terms of the current and resistance.
Kirchhoff's voltage law implies that the sum of the voltages across the resistors in series equals the source voltage. This means that the current...
1.3K
Three-Phase Voltages01:30

Three-Phase Voltages

A three-phase generator produces three voltages that are equal in magnitude but have a phase difference of 120 degrees. This identical magnitude and equal phase separated voltages are known as the balanced voltages and help to minimize power loss while ensuring a steady delivery of energy to connected loads. As voltage sources in a three-phase system can be configured in a wye or a delta formation, the loads connected to these systems can also be arranged in either configuration. This...
561