Three biomarker tests to help diagnose preterm labour: a systematic review and economic evaluation

Jo Varley-Campbell1, Rubén Mújica-Mota1, Helen Coelho1

  • 1Peninsula Technology Assessment Group (PenTAG), University of Exeter Medical School, University of Exeter, Exeter, UK.

Insights

Accurate diagnosis of preterm birth is crucial for infant health. This study assessed three diagnostic tests, finding significant uncertainty in their accuracy and cost-effectiveness, with ongoing trials expected to provide clearer results.

Area of Science:

  • Maternal-fetal medicine
  • Diagnostic test evaluation
  • Health economics

Background:

  • Preterm birth poses significant short- and long-term health risks to infants.
  • Accurate diagnosis of preterm labor is essential for appropriate medical interventions, potentially preventing unnecessary hospitalizations or transfers.

Purpose of the Study:

  • To assess the diagnostic accuracy, clinical effectiveness, and cost-effectiveness of PartoSure™, Actim® Partus, and quantitative fetal fibronectin (qfFN) tests.
  • To compare these tests against fetal fibronectin (fFN) at a threshold of 50 ng/ml for women with preterm labor symptoms.

Main Methods:

  • Systematic literature reviews were conducted for diagnostic test accuracy (DTA) and clinical effectiveness studies.
  • A model-based economic evaluation was performed to extrapolate long-term outcomes.
  • The model adapted existing frameworks, focusing on antenatal steroid use to drive health outcomes.

Main Results:

  • Twenty DTA studies were identified (delivery within 7 days), and seven (delivery within 48 hours).
  • Limited direct comparisons existed between the three tests, and significant heterogeneity was noted.
  • Economic modeling suggested Actim Partus may be more cost-effective than qfFN at 50 ng/ml, while PartoSure showed potential cost savings, though based on limited data.

Conclusions:

  • There is substantial uncertainty regarding the test accuracy and cost-effectiveness of the evaluated preterm birth diagnostic tests.
  • Ongoing UK trials with large participant numbers are expected to provide more definitive evidence.
  • Further research is needed to clarify the comparative performance and economic value of these diagnostic tools.
Abstract

Related Concept Videos

Review and Preview01:10

Review and Preview

In statistics, several tools are used to interpret the data. Measures of central tendency represent the characteristics of the data, such as mean, median, and mode. Additionally, measures of variance like standard deviation and range are used to find the spread of data from the mean. Relative standing measures the distance between data locations. Commonly used measures of relative standings are percentile, z score, and quartiles.
Percentiles are a type of fractile that partition data into...
8.3K
Review and Preview01:13

Review and Preview

Data are individual items of information obtained from a population or sample. Data may be classified as qualitative (categorical), quantitative continuous, or quantitative discrete. Because it is not practical to measure the entire population in a study, researchers use samples to represent the population. A random sample is a representative group from the population chosen by using a method that gives each individual in the population an equal chance of being included in the sample. Random...
11.0K
Diagnosing Acidosis and Alkalosis01:24

Diagnosing Acidosis and Alkalosis

Diagnosing acid-base imbalances involves systematically analyzing arterial blood samples, focusing on three key measurements: pH, bicarbonate (HCO3−) concentration, and carbon dioxide partial pressure (PCO2). This analysis follows a four-step process that helps identify the imbalance's underlying cause and nature.
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2  and...
1.1K
Random and Systematic Errors01:20

Random and Systematic Errors

Scientists always try their best to record measurements with the utmost accuracy and precision. However, sometimes errors do occur. These errors can be random or systematic. Random errors are observed due to the inconsistency or fluctuation in the measurement process, or variations in the quantity itself that is being measured. Such errors fluctuate from being greater than or less than the true value in repeated measurements. Consider a scientist measuring the length of an earthworm using a...
14.7K
Systematic Sampling Method01:17

Systematic Sampling Method

Sampling is a technique to select a portion (or subset) of the larger population and study that portion (the sample) to gain information about the population. Data are the result of sampling from a population. The sampling method ensures that samples are drawn without bias and accurately represent the population. Because measuring the entire population in a study is not practical, researchers use samples to represent the population of interest.
Systematic sampling is one of the simplest methods...
12.8K
Propagation of Uncertainty from Systematic Error01:10

Propagation of Uncertainty from Systematic Error

The atomic mass of an element varies due to the relative ratio of its isotopes. A sample's relative proportion of oxygen isotopes influences its average atomic mass. For instance, if we were to measure the atomic mass of oxygen from a sample, the mass would be a weighted average of the isotopic masses of oxygen in that sample. Since a single sample is not likely to perfectly reflect the true atomic mass of oxygen for all the molecules of oxygen on Earth, the mass we obtain from this...
1.4K