Small hamstring autograft is defined by a cut-off diameter of 7 mm and not recommended with allograft augmentation in
Huijun Kang1, Conglei Dong1, Fei Wang2
1Department of Joint Surgery, Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, China.
Purpose:
The present study was to analyze graft failure rates of hamstring tendon (HT) autografts with a cut-off graft diameter of 8 mm or 7 mm, and compare clinical outcomes between augmented small HT with an allograft and non-augmented relatively large HT in single-bundle anterior cruciate ligament reconstruction (ACLR).
Methods:
A literature search of PubMed, EMBASE, and the Cochrane Library was performed based on the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-analysis) guidelines. Studies to assess graft failure of autologous HT ACLR were reviewed, and graft failure rates with a cut-off graft diameter of 8 mm or 7 mm were further extracted. Clinical comparative studies of ACLR between augmented small HT with an allograft and non-augmented relatively large HT autografts were also included. Results are presented as risk ratio (RR) for binary data and weighted mean difference for continuous data with 95% confidence intervals (CI).
Results:
Nine studies with 2243 knees were included. Four studies examined the effect of HT autograft diameter on graft failure and five studies assessed clinical outcomes of allograft augmentation to small HT autografts. No significant difference was noted in graft failure with a cut-off diameter of 8 mm. No significant difference was found between diameters > 7 and ≤ 7 mm, but a significant difference was observed between diameters ≥ 7 and < 7 mm (RR = 0.49; 95% CI 0.26-0.92, I2 = 0%, P = 0.03). A trend towards increased risk of graft failure was noted for allograft-augmented HT compared with non-augmented HT autografts (RR = 0.43; 95% CI 0.18-1.02, I2 = 0%), but no significant differences were noted in IKDC, Lysholm, and Tegner scores between these groups.
Conclusion:
The present study did support the use of 7 mm as a reference for cut-off diameter for small HT autografts, but not allograft augmentation to small HT autografts. These findings would guide clinical application of small HT autografts in single-bundle ACLR.
Level Of Evidence:
IV.
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Defining Psychology
Cut-off Frequency of BJT
Alpha Cut-Off Frequency: Pertinent to the common-base configuration, the alpha cut-off frequency defines the upper-frequency limit at which the current gain, alpha, remains stable. As...
Brick Cutting Techniques
Cut bricks are categorized by size. Bricks cut to half their original length are called half-bats, while those cut to three-fourths their length are known as three-fourth bats.
Special types of...
Defining Social Psychology