Related Experiment Video
Updated: Jan 27, 2026

Integrating Augmented Reality Tools in Breast Cancer Related Lymphedema Prognostication and Diagnosis
Published on: February 6, 2020
Dual-Anchor Cog Threads in Fat Grafting Breast Augmentation: A Novel Scarless Method for Defining Breast Footprint
Giuseppe Visconti1, Marzia Salgarello1
1From the Department of Plastic and Reconstructive Surgery, Catholic University of "Sacro Cuore," Fondazione Policlinico Universitario "Agostino Gemelli" IRCCS.
Background:
Modern fat grafting breast augmentation allows successful breast enhancement. However, there is no fine control of breast footprint, shape, and inframammary fold. The purpose of this article is to report a novel scarless technique and to evaluate its beneficial effect by retrospectively reviewing case-control consecutive data from 51 patients.
Methods:
Fifty-one consecutive patients undergoing cosmetic breast augmentation with fat only between September of 2012 and August of 2016 were retrospectively reviewed. In the first 29 cases (56 percent), the authors did not use threads (group A, control group), whereas in the remaining 22 cases (44 percent), the authors used dual-anchor cog threads (group B, case group). Breast shape analysis was performed separately by a blinded group of plastic surgeons and by the attending surgeon using a standardized evaluation method. The BREAST-Q was used to study patient satisfaction. The Mann-Whitney U and chi-square tests were used for categorical variables, and the independent-samples t test was used for continuous variables.
Results:
No significant difference in mean graft take was found (group A, 71.2 percent; group B, 71.6 percent; p < 0.05). Group B showed a significantly higher rating than group A for lower pole profile, inframammary fold, and lateral footprint definition. No major postoperative complications were experienced in either group. In group B, no thread-related complications were experienced.
Conclusions:
The dual-anchor thread suture is a novel, effective, simple, reliable, safe, and scarless method of improving breast shape in fat grafting breast augmentation. Larger series are needed to further confirm the authors' findings.
Clinical Question/Level Of Evidence:
Therapeutic, III.
Related Concept Videos
The Anchoring-and-Adjustment Heuristic
Lipids as Anchors
The carboxy-terminal of most of the prenylated proteins, such as Ras proteins, contains...
Anchoring Junctions
Molecular Shape and Polarity
GPI Anchoring of Proteins in the ER Membrane
GPI-anchor structure
A sequence of 11 enzymatic reactions results in the synthesis of the complete GPI anchor consisting of a hydrophobic and a hydrophilic portion. The hydrophobic portion comprises phosphatidylinositol, while the hydrophilic part comprises polar groups like phosphoethanolamine,...
Tail-anchoring of Proteins in the ER Membrane

