Related Experiment Video
Updated: Jan 27, 2026

10:31
A Multi-Modal Approach to Assessing Recovery in Youth Athletes Following Concussion
Published on: September 25, 2014
13.9K
The Fainting Assessment Inventory: A 10-Item Instrument Developed to Screen for Psychogenic Nonsyncopal Collapse
1Department of Neurology, Dell Medical School, Austin, Texas.
The Journal of Nervous and Mental Disease
|March 29, 2019
Summary
A new Fainting Assessment Inventory (FAI-10) helps doctors differentiate psychogenic nonsyncopal collapse (PNSC) from syncope in young patients. This tool improves diagnosis of transient loss of consciousness, aiding clinical decision-making.
Area of Science:
- Neurology
- Psychiatry
- Clinical Diagnostics
Background:
- Conversion disorder presenting as syncope is common but often misdiagnosed.
- Differentiating psychogenic nonsyncopal collapse (PNSC) from neurally mediated syncope is clinically challenging in young patients.
- Accurate diagnosis is crucial for appropriate patient management and treatment.
Purpose of the Study:
- To develop and validate a brief, clinician-administered screening tool to distinguish PNSC from syncope in adolescents and young adults.
- To create a reliable instrument for identifying psychogenic causes of fainting.
Main Methods:
- Development of a 92-item inventory based on patient-reported features of PNSC and syncope.
- Iterative revision and validation of the inventory through multiple patient cohorts.
- Final validation using a 10-item Fainting Assessment Inventory (FAI-10) in distinct patient groups.
Main Results:
- The Fainting Assessment Inventory (FAI-10) demonstrated significant differences in scores between patients with PNSC and syncope (median scores -6 vs. 7; p < 0.001).
- High diagnostic accuracy was achieved: sensitivity (0.95), specificity (0.875), positive predictive value (0.889), and negative predictive value (0.93).
- The area under the receiver operating characteristic curve was 0.973, indicating excellent discriminative ability.
Conclusions:
- The FAI-10 is a validated, brief screening tool effective in differentiating PNSC from syncope in young patients.
- This inventory enhances clinicians' ability to diagnose various forms of transient loss of consciousness.
- The FAI-10 can improve diagnostic accuracy and guide appropriate therapeutic interventions for patients presenting with fainting episodes.
More Related Videos
Related Concept Videos
Instrument Transformers
459
Instrument transformers, comprising voltage transformers (VTs) and current transformers (CTs), play crucial roles in power substations by providing isolated replicas of current or voltage for measurement and protection purposes. Voltage transformers reduce the primary voltage to levels suitable for relay operation and measurement, while current transformers scale down the primary current. The primary winding of a current transformer often consists of a single turn, achieved by threading the...
459
Instrument Calibration
698
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
698
Instrumentation Amplifier
1.0K
An electrocardiography (ECG) machine is an essential piece of medical equipment used to monitor the electrical activity of the heart. It operates by detecting small electrical changes on the skin that result from the depolarization of the heart muscle during each heartbeat. However, these signals are in the microvolt range and can be easily overwhelmed by noise or interference.
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
1.0K
Inertial Frames of Reference
8.7K
Newton’s first law is usually considered to be a statement about reference frames. It provides a method for identifying a special type of reference frame: the inertial reference frame. In principle, we can make the net force on a body zero. If its velocity relative to a given frame is constant, then that frame is said to be inertial. So, by definition, an inertial reference frame is a reference frame where Newton's first law holds valid. Newton's first law applies to objects with...
8.7K
Non-inertial Frames of Reference
7.1K
A reference frame accelerating or decelerating relative to an inertial frame is a non-inertial frame. To help understand this, consider what taking off in an airplane, turning a corner in a car, riding a merry-go-round, and the circular motion of a tropical cyclone all have in common. All these systems are accelerating, decelerating, or rotating relative to the Earth; hence, they all are non-inertial frames. All these systems exhibit inertial forces, which merely seem to arise from motion,...
7.1K
Uncertainty in Measurement: Reading Instruments
51.1K
Counting is the type of measurement that is free from uncertainty, provided the number of objects being counted does not change during the process. Such measurements result in exact numbers. By counting the eggs in a carton, for instance, one can determine exactly how many eggs are there in the carton. Similarly, the numbers of defined quantities are also exact. For example, 1 foot is exactly 12 inches, 1 inch is exactly 2.54 centimeters, and 1 gram is exactly 0.001 kilograms. Quantities...
51.1K