Outcomes of Acute Conduction Abnormalities Following Transcatheter Aortic Valve Implantation With a Balloon
James A McCaffrey1, Talal Alzahrani1, Tanuka Datta1
1George Washington University Hospital, Washington, District of Columbia.
Abstract:
Transcatheter aortic valve implantation (TAVI) is an acceptable treatment for severe aortic stenosis in high or intermediate risk patients. Conduction abnormalities are a known complication of TAVI. Most abnormalities occur perioperatively but can develop later. The predictors of delayed conduction abnormalities are unknown. Patients who underwent TAVI at our institution were reviewed. Patients with a pre-existing pacemaker were excluded. Baseline, in-hospital, and 30-day follow-up ECGs were reviewed. Patient and procedural characteristics were analyzed to look for predictors of acute and delayed abnormalities. Ninety-eight patients were included. All valves implanted were balloon expandable, most commonly SAPIEN S3 (78%). Thirty-seven (37.7%) patients developed abnormalities before discharge. Of these patients, 20 (57.1%) had complete resolution at 30-day follow-up. No patients with new conduction abnormalities during hospitalization had additional abnormalities at 30-day follow-up. Five (5.1%) patients developed new conduction abnormalities following discharge. Overall, 22 (22.4%) patients had conduction abnormalities at 30-day follow-up which were not present at baseline. Predilatation (p = 0.003), higher ratios of balloon (p = 0.03) or valve (p = 0.05) size to left ventricular outflow tract, and previous myocardial infarction (p = 0.034) were predictive of acute conduction abnormalities. Baseline right bundle branch block (p = 0.002), longer baseline (p <0.001) and discharge (p = 0.004) QRS duration, moderate, or severe aortic insufficiency (p = 0.002) and atrial fibrillation (p = 0.031) were predictors of new conduction abnormalities after discharge. In conclusion, most new in-hospital conduction abnormalities resolve by 30-day follow-up. In-hospital conduction abnormalities are related to technical aspects of TAVI while delayed conduction abnormalities are related to baseline conduction system disease.
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
06:04Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
Related Concept Videos
Abnormal Proliferation
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Conduct Disorder
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...