Object:
The intraoperative fluoroscopy has been widely used in modern neuro-spinal surgery due to the overwhelming trend toward minimal-access surgery. However, both patients and surgical personnel were under ionizing-radiation exposure during fluoroscopy usage. Since the fluoroscopy constitutes the vast majority of radiation exposure for both surgeons and patients, the development and improvement of new interventional possibilities are of great importance and interests.
Patients And Methods:
A total of 20 patients were included in the current study, who received thoracic-spinal tumor resection via posterior midline approach. In comparison to the conventional C-Arm mobile fluoroscopy machine, the Surgical Approach Visualization and Navigation (SAVN) System was used to evaluate the effectiveness in reducing radiation.
Results:
The pain intensity and Japanese Orthopedic Association Score were equally ameliorated in patients of two groups. However, compared to C-arm group, the SAVN significantly reduced the screening time from 26.8 + 12.4 to 17.1 + 9.2 s (36.2% radiation reduction, P < 0.05), which was mainly due to the significant reduction of radiation attempts (from 12.8 + 4.9 to 7.1 + 5.5 times, P < 0.05). For patients, the direct and scatter radiation dose dropped 30.4% (P < 0.05) in the surgical region and 47.6% (P < 0.01) in the non-surgical region by using the SAVN System. Additionally, the tumor diameter/skin incision ratio increased from 0.39 + 0.4 to 0.47+ 0.28 after SAVN usage. Meanwhile, thedosimeter showed that the radiation dose to the primary surgeon was also lower in the SAVN group (72.1% reduction, P < 0.01).
Conclusion:
Comparing the conventional C-arm, the SAVN System based thoracic-spinal surgery significantly lowered radiation duration and dosage application towards both surgeons and patients.
More Related Videos
05:37Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
Related Concept Videos
Dosage Regimens: Designs and Approaches
Kidney Transplant II: Surgical Procedure
Biological Effects of Radiation
Dosage Regimen: Multiple Oral Dosage
Dosage Compensation
In addition to sexual development, the X chromosome has genes involved in autosomal functions such as brain development and the immune system. Therefore, males and females with distinct numbers of X chromosomes will...
Inflammatory Bowel Disease V: Surgical Management
Here are some common surgical interventions for IBD: