Estimation of angle kappa and pupil barycentre configuration in myopic tilted disc syndrome
Cem Cankaya1, Ercan Ozsoy2, Ersin Ersan Demirel1
1Department of Ophthalmology, Inonu University School of Medicine, Malatya, Turkey.
Background:
To evaluate the angle kappa and pupil barycentre configuration in patients with myopic tilted disc syndrome (TDS).
Methods:
Thirty-five eyes of 35 patients with TDS were included in the study. Thirty-five eyes of 35 age- and sex-matched healthy subjects were enrolled in the control group. All measurements were performed with the Lenstar LS 900. Angle kappa was calculated according to Pythagorean theorem using the x and y co-ordinates of the pupil centre. Pupil dx and pupil dy values (pupil dx: x co-ordinate of pupil centre relative to corneal apex, pupil dy: y co-ordinate of pupil centre relative to corneal apex) were used to evaluate the pupil barycentre configuration. Central corneal thickness, white to white (cornea diameter), pupil diameter, anterior chamber depth, lens thickness, and axial length were also measured.
Results:
The calculated mean angle kappa distance was 0.27 ± 0.15 mm in the TDS group and 0.29 ± 0.23 mm in the control group (p = 0.42). The mean pupil dx was -0.01 ± 0.24 mm in the TDS group and -0.17 ± 0.14 mm in the control group (p = 0.006). The mean pupil dy was -0.02 ± 0.13 mm in the TDS group and -0.05 ± 0.22 mm in the control group (p = 0.65).
Conclusions:
The pupil barycentre in TDS cases was statistically significantly closer to the corneal vertex on the horizontal plane compared to the control group. However, there was no statistically significant differences in terms of angle kappa and pupil dy values between the groups. According to our results, refractive surgery can be performed safely with respect to complications related to decentration of ablation zone and decentration of multifocal intraocular lenses in these groups of patients.
Related Concept Videos
Electron Configurations
The relative energies of the subshells determine the order in which atomic orbitals are filled (1s, 2s, 2p, 3s, 3p,...
Controller Configurations
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller...
Electron Configuration of Multielectron Atoms
Stability of Equilibrium Configuration
A stable equilibrium occurs when a system tends to return to its original position when given a small displacement, and the potential energy is at its minimum. An example of a stable equilibrium is when a cantilever beam is fixed at one end and a weight is attached to the other end. If the weight...
Configurations of BJT
The common base configuration is noted for its high voltage gain, positioning it as an ideal choice for single-stage amplifier circuits, such as microphone pre-amplifiers. A notable...
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...