Quasi-static Analysis Based on an Equivalent Circuit Model for a CMOS Terahertz Plasmon Detector in the Subthreshold

Ju-Hee Son1, Jong-Ryul Yang2

  • 1Department of Electronic Engineering, Yeungnam University, Gyeongsan 38541, Korea. sonju@ynu.ac.kr.

Related Concept Videos

Th&#233venin Equivalent Circuits01:18

Thévenin Equivalent Circuits

The household power distribution system, encompassing distribution lines and transformers, serves as the primary network. Electrical appliances within a household can be represented as load impedance. To simplify this intricate distribution system, Thévenin's theorem can be applied to create a Thévenin equivalent circuit. If an AC circuit is partitioned into two parts (circuit A and circuit B), connected by a single pair of terminals as shown in Figure 1.
662
Norton Equivalent Circuits01:16

Norton Equivalent Circuits

Norton's theorem is a fundamental concept in the field of electrical engineering that allows for the simplification of complex AC circuits. The theorem states that any two-terminal linear network can be replaced with an equivalent circuit that consists of an impedance, which is parallel with a constant current source. Figure 1 shows the AC circuit portioned into two parts: Circuit A and Circuit B, while Figure 2 depicts the circuit obtained by replacing Circuit A by its Norton equivalent...
754
Equivalent Circuits for Practical Transformers01:28

Equivalent Circuits for Practical Transformers

The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
1.4K
Pharmaceutical Equivalents01:26

Pharmaceutical Equivalents

As defined by regulatory standards, pharmaceutical equivalents require generic drug products to have identical dosage forms and chemically identical active pharmaceutical ingredients (APIs). They must adhere to compendial or applicable standards for potency, content uniformity, disintegration times, and dissolution rates. In the case of modified-release dosage forms, variations in drug content are permissible as long as the delivered amount remains consistent with the innovator drug product.
193
Equivalent Capacitance01:19

Equivalent Capacitance

Multiple capacitors can be connected in a circuit in series or parallel configuration. When the capacitor combination is connected to a battery, the potential drop across each capacitor and the magnitude of charge stored in the individual capacitor depends on the type of the connection. The capacitor combination is replaced by a single equivalent capacitor that stores the same amount of charge as the combination for a given potential difference.
The following strategies are adopted to calculate...
2.1K
Node Analysis for AC Circuits01:14

Node Analysis for AC Circuits

Consider an angioplasty system featuring a catheter equipped with a turbine, a critical tool for removing plaque deposits from coronary arteries. This intricate medical device operates using a circuit model reminiscent of a dual-node RLC circuit powered by a current-controlled voltage source.
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...
655