Mitral Valve Replacement in Infants Using a 15-mm Mechanical Valve
Osama M Eltayeb1, William J Readdy2, Michael C Mongé1
1Division of Cardiovascular-Thoracic Surgery, Ann & Robert H. Lurie Children's Hospital of Chicago, Chicago, Illinois; Department of Surgery, Northwestern University Feinberg School of Medicine, Chicago, Illinois.
The 15-mm mechanical valve is effective for infant mitral valve replacement, with a mean replacement time of 23 months. This small valve offers a viable option for pediatric patients needing mitral valve surgery.
Area of Science:
- Pediatric Cardiology
- Cardiovascular Surgery
- Biomedical Engineering
Background:
- The 15-mm mechanical valve, approved in March 2018, is the smallest available for pediatric mitral valve replacement.
- Infants often require mitral valve interventions due to congenital heart defects or other conditions.
Purpose of the Study:
- To review the outcomes of infants receiving the 15-mm mechanical valve in the mitral position.
- To determine the timing for repeat mitral valve replacement (MVR) in this pediatric population.
Main Methods:
- Retrospective chart review of 7 patients who underwent 8 MVRs with a 15-mm mechanical valve between 2006 and 2017.
- Analysis of short- and long-term outcomes, including operative mortality, complications, and need for re-intervention.
Main Results:
- No operative deaths occurred. Mean follow-up was 5.8 years.
- Four patients required repeat MVR due to somatic growth and patient-prosthesis mismatch, with a mean time to repeat MVR of 23 months.
- Two patients developed atrioventricular block requiring pacemaker implantation after their second MVR.
Conclusions:
- The 15-mm mechanical valve is a useful option for treating mitral valve disease in infants aged 2 to 12 months.
- The predicted mean time to replacement for this valve in the mitral position is 23 months, highlighting the need for growth-compatible solutions.
Related Concept Videos
Mitral Valve Prolapse I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse III: Nursing Management
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Other Nuclides: 31P, 19F, 15N NMR
While fluorine-19 and phosphorous-31 have high natural abundances (100%) and positive gyromagnetic ratios, nitrogen-15 has a low natural abundance and a negative gyromagnetic ratio. However, nitrogen-15 is still preferred over nitrogen-14 (which has a...
Mitral Stenosis I: Introduction