Related Experiment Video
Updated: Jan 27, 2026

Isolation and Quantification of Botulinum Neurotoxin From Complex Matrices Using the BoTest Matrix Assays
Published on: March 3, 2014
Immunodiffusion Detection of Clostridium botulinum Colonies
Timothy Lilly1, Donald A Kautter1, Richard K Lynt1
1Division of Microbiology, Food and Drug Administration, Washington, D.C. 20204.
Abstract:
Toxic colonies of Clostridium botulinum types A, B, E and F were detected by precipitating toxin around the colonies on agar containing antitoxin. Incorporating antitoxin in a gel diffusion agar overlay after colonies had developed was unsatisfactory for detection of type E, but worked well for all types when added directly to the plating medium. Addition of 0.6 IU of antitoxin per ml of agar gave satisfactory results with all types except type E. Zones of precipitation were produced by proteolytic strains of types A, B and F incubated at 35°C for 3 d and by nonproteolytic strains of types B and F incubated at 28°C for 4 d; type E required 1.2 IU of antitoxin per ml of agar and 5 d of incubation at 35°C. Nontoxigenic putrefactive anaerobes produced no zones of precipitation with any of the antitoxins, and toxic colonies of C. botulinum mixed among them were easily distinguished. This method was used successfully for selecting type B colonies from plates containing toxic enrichment cultures of tomato juice.
Related Concept Videos
Directly Acting Muscle Relaxants: Dantrolene and Botulinum Toxin
The binding of dantrolene to the RYR1...
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...

