Reliability and validity of measurements of cervical retraction strength obtained with a hand-held dynamometer
Frank Tudini1, Bradley Myers1, Richard Bohannon1
1a College of Pharmacy and Health Sciences, Doctor of Physical Therapy Program, Campbell University , Buies Creek , NC , USA.
Abstract:
Objectives: The purpose of this study was to describe the reliability and validity of measurements of cervical retraction strength obtained with a hand held dynamometer (HHD) from healthy adults. Background: Impaired neck muscle strength is related to neck pain, abnormal posture, and various cervical pathologies. While sophisticated devices to objectively measure neck strength exist, many are not practicable in typical orthopedic practices or have questionable validity and reliability. Methods: Forty participants were included in the analysis of neck strength using isometric testing with an HHD fixed in a cradle on a table top. The highest neck retraction force recorded in Newtons (N) for each participant, was used for data analysis. Results: Both intratester and intertester reliability were excellent as judged by intraclass correlation coefficients (ICCs) (.885 - .974) and minimal detectable change (MDC) (21.1 to 47.6 N). Validity was confirmed on the basis of expected gender and age differences (ie, men were stronger than women and younger participants were stronger than older participants). Conclusion: Fixed HHD is a reliable and valid tool for measuring isometric neck retraction strength in ostensibly healthy adults. Its value in the assessment of individuals with neck pathology awaits further examination.
Related Concept Videos
Reliability and Validity
Clot Retraction and Fibrinolysis
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...
The Equilibrium Binding Constant and Binding Strength
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Relation Between Tensile Strength and Compressive Strength of Concrete