Ambulatory urodynamic monitoring: state of the art and future directions

Benjamin Abelson1, Steve Majerus2,3, Daniel Sun1

  • 1Cleveland Clinic, Glickman Urological & Kidney Institute, Cleveland, OH, USA.

Related Concept Videos

Urodynamic Studies: Uroflowmetry01:19

Urodynamic Studies: Uroflowmetry

Uroflowmetry is a non-invasive urodynamic test designed to measure various aspects of urination, including volume, flow rate, and the time to void. This test is crucial for diagnosing and assessing conditions such as bladder outlet obstruction, bladder dysfunction, incomplete bladder emptying, incontinence, and urinary tract blockages caused by benign prostatic hyperplasia (BPH) and urethral strictures.Pre-Test Instructions:Before a uroflowmetry test, patients are typically advised to drink...
4.1K
Directing Effect of Substituents: meta-Directing Groups01:09

Directing Effect of Substituents: meta-Directing Groups

Substituents on the benzene ring that direct an incoming electrophile to undergo substitution at the meta position are called meta directors. All meta directors either have a positive charge on the atom directly bonded to the ring or a partial positive charge. These groups function by withdrawing electrons from the ring through inductive and resonance effects. Consider the carbocation intermediates formed upon the addition of an electrophile on nitrobenzene at the...
5.9K
Directing Effect of Substituents: ortho–para-Directing Groups01:14

Directing Effect of Substituents: ortho–para-Directing Groups

Ortho–para directors are substituent groups attached to the benzene ring and direct the addition of an electrophile to the positions ortho or para to the substituent. All electron-donating groups are considered ortho–para directors. They donate electrons to the ring and make the ring more electron-rich. The ring is therefore susceptible to the addition of electrophiles. Substituents such as amino, hydroxy, or alkoxy, containing lone pairs on the atom adjacent to the ring, donate...
8.4K
Directional Relays01:25

Directional Relays

Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
601
Directional Terms01:14

Directional Terms

Directional terms are essential for describing the relative locations of different body structures. For instance, an anatomist might describe one band of tissue as "inferior to" another, or a physician might describe a tumor as "superficial to" a deeper body structure. These terms often use comparative terms in pairs to trace out the relative locations of one body part to another or descriptions of body tissues like the deeper ones from superficially present with reference to...
16.2K
Self-Presentation: Self-Monitoring and Self-Handicapping02:05

Self-Presentation: Self-Monitoring and Self-Handicapping

People can go to great lengths to protect their self-image and present themselves in ways that they want others to see them. Sociologist Erving Goffman presented the idea that a person is like an actor on a stage. Calling his theory dramaturgy, Goffman believed that we use “impression management” to present ourselves to others as we hope to be perceived. Each situation is a new scene, and individuals perform different roles depending on who is present (Goffman, 1959). Think about...
43.5K