Test-retest reliability of goniometric measurements of the range of dart-throwing motion
Masahiro Mitsukane1, Hirohumi Tanabe1, Kosuke Sugama1
1Department of Rehabilitation Medicine, Shonan University of Medical Sciences: 16-48 Kamishinano, Totsuka-ku, Yokohama, Kanagawa 244-0806, Japan.
Abstract:
[Purpose] To examine the reliability of using a manual goniometer for measuring the range of dart-throwing motion. [Participants and Methods] The range of dart-throwing motion in 24 healthy participants was measured by three raters on the same day, and one rater repeated the measurement on another day of the same week. The stationary arm of the goniometer was placed along the radius, and the moveable arm was placed along the shaft of the second metacarpal, approximately 45° supinated from Lister's tubercle. All of the participants performed the dart-throwing motion on a plane that passed through the anatomical neutral wrist position, inclined 45° to the orthogonal anatomical plane. [Results] The intra-rater reliability was moderate (0.5-0.75) only for some parameters of the radial extension, and the intraclass correlation coefficients (ICCs) of all other parameters were <0.5. For the inter-rater reliability, the ICCs of all parameters were <0.5. Brand-Altman analysis revealed some fixed biases between the raters, although no proportional bias was observed. [Conclusion] The goniometric measurement procedure examined in this study appeared to be unsuitable for clinical use because of its poor reliability.
Related Concept Videos
Reliability and Validity
Range
15.9; 16.1; 15.2; 14.8; 15.8; 15.9; 16.0; 15.5
Measurements of the amount of soda in a 16-ounce can vary since different subjects record these measurements or since the exact amount - 16 ounces of liquid, was not...
Variation: Normal Distribution, Range, and Standard Deviation
¹H NMR: Long-Range Coupling
In alkenes, spin information is communicated via σ–π overlap, as seen in allylic (four-bond) and homoallylic (five-bond) couplings. These coupling interactions are stronger when the σ bond is parallel to the alkene...
Equation of Motion: General Plane motion
Moreover, the body's center of mass experiences a rotational effect as a result of these couple moments. This rotation can be articulated as the...
Distribution Reliability and Automation