Related Experiment Video
Updated: Jan 27, 2026

The Rabbit Blood-shunt Model for the Study of Acute and Late Sequelae of Subarachnoid Hemorrhage: Technical Aspects
Published on: October 2, 2014
Carotid Endarterectomy: The Need for In vivo Optical Spectroscopy in the Decision-Making on Intraoperative Shunt
Arun Balaji1, Niranjana Rajagopal2, Yasuhiro Yamada3
1Department of Neurosurgery, Kovai Medical Centre and Hospital, Coimbatore, Tamil Nadu, India.
Background:
Carotid endarterectomy (CEA) is the surgical excision of the atherosclerotic plaque in patients with severe carotid artery stenosis. It is a common surgical technique required by neurosurgeons that should be mastered. In this article, we provide an outline of the technique and multimodality adjuncts involved in performing an effective CEA with a better surgical outcome.
Materials And Methods:
We have operated a total of 14 patients in our institute from 2015 to 2018. The male to female ratio is 13:1. Four (28.5%) patients were symptomatic and 10 (71.5%) were asymptomatic; with an average percentage of carotid stenosis being 81.2% in symptomatic and 76.6% in asymptomatic patients. Two patients have undergone bilateral CEA. Intraoperative monitoring was done with continuous in vivo optical spectroscopy (INVOS). Furui's double balloon shunt system was used to maintain blood flow from common carotid artery to the internal carotid artery, thus preventing cerebral ischemia in selected cases with significantly lateralized cerebral oximetry (CO) recordings.
Results:
Of the 14 patients with 16 CEA procedures, continuous INVOS monitoring was used in 12 CEA procedures. Of the 12 cases, only 5 (41.6%) needed a shunt. Furui's shunt was not used in 7 (58.3%) CEA procedures, where there were no changes in the intraoperative CO and these patients had an uneventful postoperative period. INVOS monitoring not only reduced the use of routine intraoperative shunt but also reduced the total surgical time and thus aided in preventing neurological complications.
Conclusion:
CEA should be strongly considered for symptomatic patients with >70% of carotid stenosis and in patients with 50%-69% stenosis if no other etiological basis for the ischemic symptoms can be identified. Continuous INVOS monitoring is mandatory for the decision of the use of intraoperative shunt, which reduces the perioperative morbidity and mortality significantly.
More Related Videos
05:54Stereo-Electro-Encephalo-Graphy SEEG With Robotic Assistance in the Presurgical Evaluation of Medical Refractory Epilepsy: A Technical Note
Published on: June 13, 2016
09:40Phosphorus-31 Magnetic Resonance Spectroscopy: A Tool for Measuring In Vivo Mitochondrial Oxidative Phosphorylation Capacity in Human Skeletal Muscle
Published on: January 19, 2017
Related Concept Videos
Shunt Admittances
To model this effect, the method of images is employed. This method involves replacing the Earth with an image conductor that mirrors the original...
Decision Making
Automatic decision-making is fast, intuitive, and relies on gut feelings...
Decision Making: P-value Method
First, a specific claim about the population parameter is proposed. The claim is based on the research question and is stated in a simple form. Further, an opposing statement to the claim is also stated. These statements can act as null and alternative hypotheses: a null hypothesis would be a neutral statement while the alternative hypothesis can...
Decision Making: Traditional Method
First, a specific claim about the population parameter is decided based on the research question and is stated in a simple form. Further, an opposing statement to this claim is also stated. These statements can act as null and alternative hypotheses, out of which a null hypothesis would be a...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Atomic Fluorescence Spectroscopy