Penumbra detection in acute stroke with perfusion magnetic resonance imaging: Validation with 15 O-positron emission

Olivier Zaro-Weber1,2,3, Hermann Fleischer1,2,3, Lucas Reiblich1,2,3

  • 1Max Planck Institute for Neurological Research, Cologne, Germany.

Annals of Neurology
|April 3, 2019
PubMed
Abstract

Insights

Magnetic resonance imaging (MRI) Tmax maps accurately identify the ischemic penumbra, the brain tissue at risk in stroke. This method reliably guides reperfusion therapy decisions up to 48 hours after stroke onset.

Area of Science:

  • Neurology
  • Radiology
  • Medical Imaging

Background:

  • Accurate identification of the ischemic penumbra is crucial for selecting acute stroke patients for reperfusion therapies.
  • Current methods for penumbra detection face limitations, especially beyond established time windows.

Purpose of the Study:

  • To validate magnetic resonance imaging (MRI) mismatch-based penumbra detection against quantitative positron emission tomography (PET).
  • To optimize perfusion-weighted (PW) MRI measures for detecting the ischemic penumbra in acute ischemic stroke.

Main Methods:

  • Ten patients with acute/subacute ischemic stroke underwent PW/diffusion-weighted MRI and quantitative 15O-PET within 48 hours.
  • Validation involved comparing PW measures, including time-to-maximum (Tmax), against PET-defined penumbra using receiver-operating-characteristic analysis.
  • A separate group of 23 patients was used for comparative validation.

Main Results:

  • The PW Tmax map demonstrated the best performance (area-under-the-curve = 0.88) in detecting penumbral tissue up to 48 hours post-stroke.
  • An optimal threshold of Tmax >5.6 seconds achieved >80% sensitivity and specificity for discriminating penumbra from oligemia.

Conclusions:

  • The PW Tmax measure exhibits excellent performance for detecting the penumbral flow threshold in ischemic stroke.
  • Tmax >5.6 seconds reliably identifies the penumbra, supporting treatment decisions up to 48 hours and potentially extending reperfusion therapy windows.

Related Concept Videos

Positron Emission Tomography01:29

Positron Emission Tomography

Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
7.1K
Imaging Studies II: Positron Emission Tomography and Scintigraphy01:25

Imaging Studies II: Positron Emission Tomography and Scintigraphy

Positron Emission Tomography (PET) is a medical imaging technique that provides crucial insights into the body's physiological functions at a molecular level. It is an indispensable resource for diagnosing, staging, and monitoring various illnesses, notably cancer, neurological disorders, and cardiovascular conditions.
Fundamental Principles of PET
535
Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
9.2K
Imaging Studies IV: Magnetic Resonance Imaging01:27

Imaging Studies IV: Magnetic Resonance Imaging

Introduction:Magnetic Resonance Imaging, or MRI, can include a specialized imaging technique of the urinary system known as Magnetic Resonance Urography (MRU). This radiation-free technique uses strong magnetic fields and radio waves to produce detailed images with the help of a computer. MRU is particularly effective for visualizing fluid-filled structures like the kidneys, ureters, and bladder.Applications of MRI in the Genitourinary SystemKidneys and Ureters: MRI detects tumors, cysts,...
249
Atomic Nuclei: Magnetic Resonance01:05

Atomic Nuclei: Magnetic Resonance

The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
1.2K
Resonance02:52

Resonance

The Lewis structure of a nitrite anion (NO2−) may actually be drawn in two different ways, distinguished by the locations of the N-O and N=O bonds.
64.9K