LMA® Protector™ versus traditional LMA to perform endobronchial ultrasound-guided transbronchial needle aspiration: a
Enzo Zamparelli1, Alfonso Fiorelli2, Giuseppe La Cerra3
1Unit of Anesthesiology and Intensive Care, Vincenzo Monaldi Hospital, Naples, Italy - enzozamparelli@gmail.com.
Background:
The aim of this study was to evaluate the use of laryngeal mask airway (LMA)® Protector™ by comparison with traditional LMA for performing endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA).
Methods:
This was a retrospective observational single-center study including 143 patients who underwent EBUS-TBNA for mediastinal staging of lung cancer. Patients were retrospectively divided into two groups based on whether a traditional LMA (traditional LMA group) or LMA Protector was used. Anesthesiologist outcomes, diagnostic yield of EBUS-TBNA, and complications related to the procedure were computed for each group and statistically compared.
Results:
LMA traditional group and LMA Protector group counted 70 and 73 patients, respectively. LMA traditional group versus LMA Protector group showed no significant difference on time of LMA insertion (120±25 vs. 118±39 s; P=0.49), reposition rates (18% vs. 16%; P=0.78); systolic pressure (140±55 vs. 118±37 mmHg; P=0.59); diastolic pressure (82±15 vs. 90±26 mmHg; P=0.39); heart rate (82±9.9 vs. 83±20 bpm; P=0.49); SpO2 values (93±21% vs. 92±14%; P=0.63); diagnostic accuracy (91.3% vs. 92%; P=0.95), and patients' complications as nausea (4% vs. 3%; P=0.61); vomiting (3% vs. 1%, P=0.96); gastric aspiration (7% vs. 1%; P=0.08); and sore throat (7% vs. 3%; P=0.22). Conversely, LMA traditional group versus LMA Protector group presented a longer procedural time (47±23 vs. 38±17 s; P=0.02), higher number of passage to biopsy target lesion (4±0.5 vs. 3.1±0.6; P=0.01); higher rate of balloon ultrasound rupture (11% vs. 1%; P=0.01).
Conclusions:
EBUS-TBNA conducted with LMA Protector is a useful strategy that reduced the procedural time and in theory ensured the comfort of patients. Our results should be confirmed by larger, prospective, randomized studies.
More Related Videos
06:03Use of Electromagnetic Navigational Transthoracic Needle Aspiration E-TTNA for Sampling of Lung Nodules
Published on: May 23, 2015
04:04Endobronchial Ultrasound-guided Intratumoral Injection of Cisplatin for the Treatment of Isolated Mediastinal Recurrence of Lung Cancer
Published on: February 12, 2017
Related Concept Videos
Performing a Simple Data Analysis using MS-Excel Function
SUM: This function calculates the total sum of a range of values. It's the foundation for aggregating data, essential for determining overall trends and totals in datasets.
AVERAGE: It computes the mean value of a given set of numbers, providing a quick insight into the central...
Decision Making: Traditional Method
First, a specific claim about the population parameter is decided based on the research question and is stated in a simple form. Further, an opposing statement to this claim is also stated. These statements can act as null and alternative hypotheses, out of which a null hypothesis would be a...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Traditional Level Of Health Care System
The preventive healthcare service includes tests for screening. Preventive health care services include identifying and reducing disease risk...
Exercise and Muscle Performance
Endurance exercises
Endurance exercises involve running, swimming, or cycling, which require repetitive movements with low force output. When a person engages in endurance exercise, a few noticeable changes occur in their skeletal muscles. For instance, the number of capillaries...
Pathophysiology of Cardiac Performance