Related Experiment Video
Updated: Jan 26, 2026

Recognition of Epidermal Transglutaminase by IgA and Tissue Transglutaminase 2 Antibodies in a Rare Case of Rhesus Dermatitis
Published on: December 15, 2011
Autoantibodies to Mi-2 alpha and Mi-2 beta in patients with idiopathic inflammatory myopathy
Michaelin Richards1, Ignacio García-De La Torre2, Yelitza C González-Bello3
1Research and Development, Inova Diagnostics, San Diego, CA, USA.
Objectives:
The objective of this study was to compare the results obtained from different assays for the detection of anti-Mi-2 antibodies, which are important markers in the diagnosis of DM.
Methods:
The study included 82 patients (68 females/14 males), most of whom had DM (n = 57), followed by PM (n = 16) and juvenile DM (n = 9). All samples were tested using a novel particle-based multi-analyte technology (PMAT) (Inova Diagnostics, research use only) in parallel with a line immunoassay (LIA: Euroimmun). To assess clinical specificity for the PMAT assay, a total of 775 disease and healthy controls were tested.
Results:
29 samples were positive by at least one test for anti-Mi-2 antibodies. Of those, 24 were Mi-2β LIA+, five were Mi-2α LIA+ and 23 Mi-2 PMAT+. The comparison shows varying agreement between the different methods (kappa 0.27-0.77). When LIA results were used as reference for receiver operating characteristics analysis, high area under the curve values were found for both PMAT vs LIA Mi-2α and LIA Mi-2β. When analysing the results in the context of the myositis phenotype, PMAT associated closest with the DM phenotype. In the control group, 3/775 controls (all low levels) were anti-Mi-2+ resulting in a sensitivity and specificity of 28.1% and 99.6%, respectively.
Conclusion:
Overall, good agreement was found between LIA and PMAT for anti-Mi-2 antibodies, which is important for the standardization of autoantibodies. Anti-Mi-2β antibodies measured by PMAT tend be more highly associated with the clinical phenotype of DM.
More Related Videos
05:58A Novel Nicotinamide Adenine Dinucleotide Correction Method for Intracellular Ca2+ Measurement with Fura-2-Analog in Live Cells
Published on: September 20, 2019
09:38Minimally Invasive Isolated Limb Perfusion (MI-ILP) for Locally Advanced Melanomas and Sarcomas of the Extremity
Published on: January 31, 2025
Related Concept Videos
meta-Directing Deactivators: –NO2, –CN, –CHO, –⁠CO2R, –COR, –CO2H
2° Amines to N-Nitrosamines: Reaction with NaNO2
SN2 Reaction: Kinetics
In a chemical reaction, a relationship exists between the concentration of reactants and the rate at which the reaction proceeds. The study to measure this relationship is known as the kinetics of a chemical reaction. Kinetic studies are used to deduce the rate law of a chemical reaction, which provides information about the species involved during the transition state of the rate-determining step. Thus, kinetic studies help to derive the mechanism of a...
SN2 Reaction: Mechanism
The presence of the more electronegative halogen in the substrate creates a polarized carbon-halide bond. The halide pulls the electron cloud generating an electrophilic center at the carbon atom. Thus, the carbon atom carries a partial positive charge while the halide has a...
SN2 Reaction: Transition State
When the nucleophile approaches the electrophilic carbon with its lone pairs, the halide acts as a leaving group and moves away with the electron-pair bonded to the carbon. Dotted partial bonds represent the bonds being formed or broken...
SN2 Reaction: Stereochemistry
If the substrate is an achiral molecule at the α-carbon, the inversion of configuration is not...