Related Experiment Video
Updated: Jan 26, 2026

Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Four-Dimensional Computed Tomography Scanning for Dynamic Wrist Disorders: Prospective Analysis and Recommendations
Renee Carr1, Simon MacLean2, John Slavotinek3
1College of Medicine and Public Health, Flinders University, Adelaide, Australia.
Abstract:
Background Four-dimensional computed tomography (4D CT) is a rapidly developing diagnostic tool in the assessment of dynamic upper limb disorders. Functional wrist anatomy is incompletely understood, and traditional imaging methods are often insufficient in the diagnosis of dynamic disorders. Technique This study has developed a protocol for 4D CT of the wrist, with the aim of reviewing the clinical utility of this technology in surgical assessment. A Toshiba Aquilion One Vision scanner was used in the protocol, in which two- and three-dimensional "static" images, as well as 4D "dynamic" images were produced and assessed in the clinical context of each patient. These consisted of a series of multiple 7-second movement clips exploring the nature and range of joint motion. Patients and Methods Nineteen patients with symptoms of dynamic instability were included in the study. Patients were assessed clinically by two orthopaedic surgeons, and qualitative data were obtained from radiological interpretation. Results The study demonstrated varied abnormalities of joint movement attributed to a range of wrist pathology, including degenerative arthritis, ligamentous injuries, Kienbock's disease, and pain following previous surgical reconstructive procedures. Interpretation of the 4D CT scan changed the clinical diagnosis in 13 cases (68.4%), including the primary (15.8%) or secondary diagnosis (52.6%). In all cases, the assessment of the dynamic wrist motion assisted in understanding the clinical problem and led to a change in management in 11 cases (57.9%). The mean effective radiation dose for the scan was calculated at 0.26 mSv. Conclusion We have found that the clinical utility of 4D CT lies in its ability to provide detailed information about dynamic joint pathology not seen in traditional imaging, targeting surgical treatment. Limitations to the use of 4D CT scan include lack of availability of the technology, potential radiation dose, and radiographer training requirements, as well as limited understanding of the nature of normal motion.
More Related Videos
10:23Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023
11:49Using High Resolution Computed Tomography to Visualize the Three Dimensional Structure and Function of Plant Vasculature
Published on: April 5, 2013
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...
Dimensional Analysis
In fluid mechanics, dimensional...
Dimensional Analysis
Dimensional analysis allows us to analyze and compare physical quantities on a...
Dimensional Analysis
Imaging Studies III: Computed Tomography