Related Experiment Video
Updated: Jan 26, 2026

Author Spotlight: Harnessing Mouse Eye Chambers for Noninvasive Liver Spheroid Studies
Published on: March 29, 2024
Differences in Anterior Chamber Angle Assessments Between Gonioscopy, EyeCam, and Anterior Segment OCT: The Chinese
Benjamin Y Xu1, Anmol A Pardeshi1, Bruce Burkemper2
1USC Roski Eye Institute, Department of Ophthalmology, Keck School of Medicine at the University of Southern California, Los Angeles, CA, USA.
Purpose:
To quantify interquadrant differences in anterior chamber angle (ACA) configuration assessed on gonioscopy, EyeCam, and anterior segment optical coherence tomography (AS-OCT) in a cohort of Chinese Americans.
Methods:
Subjects aged 50 years or older were recruited from the Chinese American Eye Study (CHES), a population-based epidemiologic study in Los Angeles, CA. Each subject underwent a complete ocular exam, including gonioscopy, EyeCam, and AS-OCT, under dark ambient lighting. Gonioscopy and AS-OCT imaging and EyeCam image grading were performed by trained ophthalmologists.
Results:
Seven hundred nine eyes from 709 subjects were analyzed. Less anatomic variation among the quadrants was detected on gonioscopy and EyeCam compared with AS-OCT (P < 0.05). The mean gonioscopy grade, EyeCam grade, and AS-OCT measurement for each quadrant varied by up to 10.3%, 6.4%, and 46.2% of the superior quadrant value, respectively. There were significant interquadrant differences (P < 0.05) among mean AOD750 measurements when grouping by quadrant and gonioscopy or EyeCam grade. Mean AOD750 measurements were smallest for the superior quadrant by between 14.3% and 38.1% and 17.4% and 37.9% on gonioscopy and EyeCam, respectively, compared with other quadrants.
Conclusions:
Gonioscopy and EyeCam significantly underrepresent anatomic variations of the ACA compared with AS-OCT. Gonioscopy or EyeCam grades from different quadrants do not appear to be comparable or interchangeable, which supports reconsideration of current definitions and methods used to diagnose and manage primary angle closure disease.
Translational Relevance:
AS-OCT imaging raises concerns about current clinical definitions and methods that rely gonioscopy or EyeCam to assess the ACA.
Related Concept Videos
Muscles of the Anterior Neck
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Electric Potential and Potential Difference
When a test charge moves from the initial to the final position, the electric potential difference between those positions is defined as the ratio of the change in the potential energy to the charge on the...
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Identifying Statistically Significant Differences: The F-Test