Morphine infusor pump switch to oral methadone
Juan Santos Suárez1, Gema Del Valle Arnáez2
1Palliative Care, Servicio de Salud del Principado de Asturias (SESPA), Oviedo, Spain juansantos.paliativos@gmail.com.
Abstract:
Between 2014 and 2017, four patients with widespread cancer were referred to a home palliative care team from a hospital in Oviedo (Spain) with subcutaneous elastomeric infusion pump containing 180-260 mg/day of morphine for previously uncontrolled pain. 3-4 rotations were performed over 5-11 days, gradually substituting morphine for oral methadone (three times a day) to minimise the risks of rapid conversion, with a highly variable final subcutaneous morphine:oral methadone ratio (5:1 to 17:1), guided by the absence of pain, and to enhance the patient's functional capacity avoiding device dependence. The final methadone dose varied between 15 and 39 mg/day. There was daily telephone supervision and visits every 2-4 days. Patient demise occurred 56, 111, 168 and 350 days following the opioid conversion, and methadone was maintained until then. In all cases and prior to concluding the rotation, pain was controlled and sleepiness had subsided.
Related Concept Videos
Switching of BJT
Cut-off Mode ("Off" State): In this state, both the emitter-base and collector-base junctions are...
Opioid Analgesics: Morphine and Other Natural Cogeners
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Pumped Concrete
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
Refrigerators and Heat Pumps
A household refrigerator removes heat from...